75
I/O#1 Low level (ID=1303)
I/O#1 logic operand (ID=1304)
I/O#1 averaging length (ID=1305)
8.7.2
I/O#1 priority (ID=1301)
Parameter defines I/O property type of priority: 0 is low, 1 – high, 2 – panic.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
0
I/O#1 property parameter
(ID=1300)
I/O#1 High level (ID=1302)
I/O#1 Low level (ID=1303)
I/O#1 logic operand (ID=1304)
I/O#1 averaging length (ID=1305)
S8
8.7.3
I/O#1 High level (ID=1302)
Parameter defines high value of triggered I/O property. This parameter is used to set
thresholds for I/O properties to generate events.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
-2147483648 2147483647
1
I/O#1 property parameter (ID=1300)
I
/O#1
priority
(ID=1301)
I/O#1 Low level (ID=1303)
I/O#1 logic operand (ID=1304)
I/O#1 averaging length (ID=1305)
S32
8.7.4
I/O#1 Low level (ID=1303)
Parameter defines low value of triggered I/O property. This parameter is used to set
thresholds for I/O properties to generate events.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
-2147483648 2147483647
0
I/O#1 property parameter (ID=1300)
I
/O#1 priority (
ID
=1301)
I/O#1 High level (ID=1302)
I/O#1 logic operand (ID=1304)
I/O#1 averaging length (ID=1305)
S32
8.7.5
I/O#1 logic operand (ID=1304)
Parameter defines when event is sent: 0 – on range exit, 1 – on range entrance, 2 – both,
3 – monitoring, 4 – hysteresis.