39
5.15
Features settings
For more information about available Scenarios, Trip, Geofencing and iButton list, refer to
5.4 chapter.
5.15.1
Scenarios settings
In Scenarios window four different scenarios are available, two per each Digital Output
(DOUT). Only one per digital output can be active at a same time, e.g. DOUT1 can have either
Green driving
or
Over Speeding enabled, DOUT2 can have either Authorized Driving
or
Immobilizer enabled.
Figure 33 Scenarios configuration
Digital Output (open drain grade) usage in scenarios:
Green Driving
DOUT1 is ON for:
3sec. if detected value is over (0; 30] % from preconfigured allowed value
5sec. if detected value is over (30; 50] % from preconfigured allowed value
7sec. if detected value is over (50; -] % from preconfigured allowed value
After period of time DOUT1 is turned OFF.
Over Speeding
DOUT1 is ON, while vehicle speed exceeds parameter value. DOUT1 is activated until
current speed decreases below parameter value.
Authorized driving
DOUT2 is continuously OFF. Dout2 turns ON if Ignition turns ON (Din1=1). After authorizing
iButton (iButton ID is read and it matches the ID from the iButton list), DOUT2 turns OFF. After
successful authorization DIN1 (ignition) can be turned OFF (Din1=0) for no longer than 30
seconds, otherwise authorization must be repeated.
Immobilizer
DOUT2 is continuously OFF. Dout2 turns ON if Ignition turns ON (Din1=1). After iButton ID
is read (any iButton is attached), DOUT2 turns OFF. After iButton identification DIN1 (ignition)
can be turned OFF (Din1=0) for no longer than 30 seconds, otherwise immobilizer must be
repeated.