number). All S registers except those identified as “read only” can be changed directly as described in
Chapter 10. Table 5 is a summary of the S registers.
Note:
Register numbers preceded by * are unique to the T-311. Those flagged with
⇐
are variations
from the Hayes S registers. All others are comparable to the corresponding Hayes S registers.
Table 5 S Register Summary
Register
Item
Default value
Value range
S0
Number of rings for auto answer
0
0-255
S1
Ring counter
Read only
NA
S3
End-of-line character <CR>
Carriage return
(013)
0-127
S4
Line feed character <LF>
Line feed (010)
0-127
S5
Backspace character
Backspace (008)
0-32, 127
S6
Pause before dialing
2 seconds
0-255
S7
Call completion timeout
30
0-255
S8
Pause for comma in dial string
2 seconds
0-255
S10
Call disconnect timeout
0 (disabled)
1-127
S11
DTMF dialing rate
70
50-255
S13
RS-232 port data format
8
NA, bit mapped
S14
Option configuration
203
NA, bit mapped
S*0
Ringback tones before disconnect
0
0-255
S*2
Verification and display
67
NA, bit mapped
S*3
Flash interval
5 (hundreds of )
3-11
S*4
Baud rate
2 (1200 baud)
0-5
S*5
Receiver status
Read only
NA
S*6
Telephone line status
Read only
NA
S*7
Head/handset status
Read only
NA
S0
Auto Answer
This command holds the number of rings after which the T-311 automatically answers an incoming
call. A value of 0 disables the automatic answer function.
Valid range:
0-255
Units:
Rings
Default:
0
T-311
Page 32