Telonics TCA-500C Combo Amp
24
PB-009289 Rev E
TCA-500C
C
OMBO
A
MP
C
ONTROL
F
UNCTIONS
&
J
ACKS
:
R
EAR
P
ANEL
(
CONTINUED
)
Switched AC
Outlet Socket and
Auxiliary Fuse
(rear panel)
WARNING - Before checking this fuse ALWAYS ensure the
combo is disconnected from the mains supply.
Switched 110-120VAC outlet, fused with a 2 amp 250VAC 5x20mm
glass Slow Blow fuse. Note: This outlet is a C14 connector in the export
version.
To allow the combo to be powered from a single AC cord, a
switched AC power socket is provided to power up an external
effects unit.
WARNING
– Mains voltage is present on this connection – DO
NOT plug in any device into this socket other than those that accept
the AC mains voltage. If any liquid is spilled on the combo in this
area UNDER NO CIRCUMSTANCES should the combo be used,
and the AC mains cord plug should be IMMEDIATELY
disconnected from the AC mains supply socket.
The output voltage from the Switched AC socket will be the same as
applied to the combo AC mains cord plug. Always check to be
certain that your effects processor voltage suits the supply voltage
applied to the TCA-500C Combo Amplifier.
Note: the power taken by the effects processor should not exceed 50
Watts.
24 VDC OUT
(Combo Model)
(Head Unit Model)
This jack is in parallel with the 24VDC Out on the front panel. The power
supply is isolated from the main amplifier and can supply 0.2 amps
maximum.
Note: Center pin is Positive
(+).
9 VDC OUT
(Mini-Combo
Models Only)
This jack is available to provide 9 volts (regulated) DC power (1.0 amps
maximum) for external effects units which the user might wish to use with
the Mini-Combo Models.
Note: center pin is Negative (-) to comply with “stomp box
convention” standards.
Fuse