Input settings

Inputs can be used in different operation modes [

In (e.g.:1;2)tab/types of Input

]:

• 

24h normal: continuously monitors input, in case of alarm sends signals.

• 

on (e.g.:1;2) tab/Inverted operation

: in normal position input expects short-circuit, if function is checked in normal position it 

expects cut.

• 

sMs/Voice call about restore: if checked, notification is received about input restore also. In case of sMs (

other/Restore

) mes-

sage is sent.

• 

siren sound

: In case of VoICe call, emits a siren sound (20-30 seconds).

• 

sending a voice message

: In case of VoICe call, it plays recorded voice. 

Attention! If neither siren sound, nor voice message is checked, GsM automatically disconnects line, and there is no sound! siren 
sound and voice message can be used together, in this case siren sounds shortly then voice message is played. 

Power monitor

the device constantly monitors incoming voltage (12V, GnD terminal block), if voltage goes below 10V (external battery low) it is 
capable of sending alarm. notification about restore can be requested.

Summary of Contents for EasyCon GSM

Page 1: ...EasyCon GSM Installation manual...

Page 2: ...t settings page 4 Input settings page 5 Power monitor page 5 Tamper page 6 Life signal page 6 SMS forward page 6 Description of voice calls page 6 Description of SMS page 7 Calendar of events page 7 E...

Page 3: ...erferences such as electric motors or transformer of the alarm system Do not install device in wet or high humid places Connection of the antenna You may connect the antenna to a SMA plug In case of p...

Page 4: ...a regular mobile phone or you may view edit the SIM card s address book in the Caller ID tab First you need to upload it with the Read button then after editing write it in with the Send but ton The...

Page 5: ...restore also In case of SMS Other Restore mes sage is sent Siren sound In case of VOICE call emits a siren sound 20 30 seconds Sending a voice message In case of VOICE call it plays recorded voice Att...

Page 6: ...required You do not need to listen to the siren sound voice message answering the phone means confirmation Avoid ing voicemail confirmation your ringtone time needs to be set shorter than your voicema...

Page 7: ...the programme where it is displayed as a graph When performing maintenance you can check for constant signal strength The module is capable of storing signal strength data for the last 20 years SMS p...

Page 8: ...tttt types of the two inputs t can be a value between 0 and 5 a letter i inverted or n non inverted needs to be put before the value E g i1 normal inverted input 0 Input off 1 24 hour normal input 2 N...

Page 9: ...onitoring station the use of high gain antenna is recommended since perfect transmission requires suf ficient signal strength above 60 Monitoring station signals Input1 Input2 Power supply Periodic li...

Page 10: ...e programming cable if the name of the device shows click start in the telephone tab enter the phone numbers you wish to notify then fill in the other tabs finally transfer the configuration and save...

Page 11: ...tellsystem eu EasyCon GSM page 11 TellSystem Communication CE certificate...

Reviews: