Input settings
Inputs can be used in different operation modes [
In (e.g.:1;2)tab/types of Input
]:
•
24h normal: continuously monitors input, in case of alarm sends signals.
•
on (e.g.:1;2) tab/Inverted operation
: in normal position input expects short-circuit, if function is checked in normal position it
expects cut.
•
sMs/Voice call about restore: if checked, notification is received about input restore also. In case of sMs (
other/Restore
) mes-
sage is sent.
•
siren sound
: In case of VoICe call, emits a siren sound (20-30 seconds).
•
sending a voice message
: In case of VoICe call, it plays recorded voice.
Attention! If neither siren sound, nor voice message is checked, GsM automatically disconnects line, and there is no sound! siren
sound and voice message can be used together, in this case siren sounds shortly then voice message is played.
Power monitor
the device constantly monitors incoming voltage (12V, GnD terminal block), if voltage goes below 10V (external battery low) it is
capable of sending alarm. notification about restore can be requested.