tellsystem.eu
EasyCon GSM
page 6.
TellSystem Communication
Life signal
settings can be made on
Life signal
tab: it is recommended to request a test message every week or every second week to check
proper operation of device. Frequency (every 1-255 days) and time of message can be set. only full hours of the clock can be set:
e.g. 12:00, 13:00, etc. You can also set how many days after setting you wish to receive the first message. Life signal can only be
requested as sMs, with a custom message.
SMS forward
other tab/sMs Forward
: with this function the module forwards every uninterpretable message to a preset phone number. this
is a useful function to receive the pre-paid sIM card balance message.
Description of voice calls
every outgoing VoICe call needs to be confirmed by user. Answering the phone qualifies as confirmation, no code or pressing of
button is required. You do not need to listen to the siren sound/voice message, answering the phone means confirmation. Avoid-
ing voicemail confirmation, your ringtone time needs to be set shorter than your voicemail pickup. this way the module discon-
nects the phone line before voicemail confirmation (
other tab/Ringtone time
). By default, if anyone answers the call, the alarm is
confirmed and no further numbers are called. If circular calling function is turned on, everyone has to confirm the call.
With the number of redials you can set how many outgoing calls the module can make in one alarm period. Unless for a good
reason do not set a value less than 50.
An 8 second message can be recorded for the following signals: inputs, power failure alarm.
You may record an identification message of less than 16 seconds. For practical reasons you may want to include the place of in-
stallation and name of facility in the message. this message is played before the voice message. Its use is not compulsory.
order of voice messages: siren sound + identification m Alarm message