FlexSym-ONT205-Installation-Guide
Page 13 of 38
UPS
Special connector for DC power input from the adapter (recommended). An
optional Uninterruptible Power Supply, aka Backup Battery Unit (not yet
available), also plugs into this connector.
DC 54V
Special connector for DC power input for remote bulk DC power
GE1-GE4 (gigabit Ethernet)
MG5 (Multi-Rate Port)
RJ-45 port connectors
PON optical connector
(unlabeled)
SC/APC (Subscriber Connector/Angled Port Connector) single-mode optical
fiber connector
PoE Output to PDs (When DC Power Input is From the 150-W AC Adapter)
Class per IEEE802.3
Total Pwr
(Watts)
PD (Watts)
PSE Pwr
(Watts)
No. of PDs
Class 0 (unclassified)
140
12.95
15.4
4
Class 1
4
5
4
Class 2
7
9
4
Class 3 (802.3af )
12.95
15.4
4
Class 4 (802.3at)
25.5
30
2
Compliance
PON
ITU-T G.984.1, G.984.2, G.984.2 amd1, G.984.3, G.984.4, G.983.2, G.9807.1,
G9807.2, G.987.3, G987.4
FDA 21 CFR 1040.10 and 1040.11
EMC
FCC 47 CFR part 15 (Class B), EN55022:2010, EN55024:2016, and EN 61000-3-3,
2008
Safety
UL 60950-1 Ed.02; UL2043 plenum fire tested
CE
Laser
ITU-T Rec.G.984.2 (Class B+), G983.3 FDA 21 CFR 1040.10 and 1040.11, Class I
IEC 60825, Class I
Ethernet
IEEE 802.1ad, 802.1d, 802.1q, 802.3
Optical
Transmitter
Minimum
Nominal
Maximum
Notes