LE910Cx HW User Guide
1VV0301298 Rev. 33
Page 42 of 128
2021-06-29
Not Subject to NDA
Models
ON
↔
VAUX/PWRMON
ON
↔
SW_RDY
LE910C1-SA
Typ. 13 Sec
Typ. 16 Sec
LE910C1-ST
LE910C1-SV
LE910C1-EUX
Typ. 10 Sec
Typ. 20 Sec
LE910C1-SAX
LE910C1-SVX
Table 18: Timing of VAUX/PWRMON and SW_RDY
Note:
SW_RDY signal is available on GPIO_08 (by default GPIO_08
functions as SW_RDY)
Note: To check whether the LE910Cx has completely powered on,
monitor the SW_RDY hardware line. When SW_RDY becomes high,
the module is completely powered on and is ready to accept AT
commands.
Note:
During the SW initialization of the LE910Cx, the SW configures
all pads and interfaces to the desired mode. When PWRMON goes
high, this indicates that the initialization of all I/O pads is completed.
Note:
Do not use any pull-up resistor on the ON_OFF_N line as it is
pulled up internally. Using a pull-up resistor may cause latch-up
problems on the LE910Cx power regulator and improper powering
on/off of the module. The ON_OFF_N line must be connected only in
an open-collector configuration.
Note: For systems not requiring controlled power ON/OFF,
automatic power on can be supported by shorting the ON_OFF
signal directly to GND