From the remote IP-223 Multicast Address Setup window, in:
1. Line 1’s Rx Port field, enter the
same port number
as the local IP-223’s Tx port
number for Line 1 (for example 1072).
2. Line 1’s Tx Port field, enter the
same port number
as the local IP-223’s Rx port
number for Line 1 (for example 1054).
3. Line 2’s Rx Port field, enter the
same port number
as the local IP-223’s Tx port
number for Line 2 (for example 1073).
4. Line 2’s Tx Port field, enter the
same port number
as the local IP-223’s Rx port
number for Line 2 (for example 1055).
5. Click
Save to EEPROM
.
The EEPROM window appears.
6. Click
Save Parameters
.
All configurations are permanently saved to the IP-223 console.
NOTE:
The range for the Rx Port field and Tx Port field is
1054
to
65535
.
5.2.2
Remote IP-223 Per Line Setup Windows Line 1 and 2
REFERENCE:
For more information, see the IP-223 Technical Manual (P/N
803641) or appropriate application note for any special IP-223
configuration requirements on Line 1 and Line 2 for the type of
radio connected.