background image

IP-223 to RTS Intercom Products

14 

AN-DISPATCH-035

FIGURE 9. Per Line Setup Window, Local Mode–Line 2

Summary of Contents for IP-223 to RTS

Page 1: ...AN DISPATCH 035 Rev A 05 AUG 2009 IP 223 to RTS Intercom System ...

Page 2: ...4 1 3 Per Line Setup Window Line 1 11 4 1 4 Per Line Setup Window Line 2 13 5 0 WAN LAN Remote Configuration Example 15 5 1 Local IP 223 Setup 15 5 1 1 Local IP 223 Multicast Address Setup Window 16 5 1 2 Local IP 223 Per Line Setup Window Lines 1 2 18 5 2 IP 223 Remote Setup 19 5 2 1 Remote IP 223 Multicast Address Setup Window 19 5 2 2 Remote IP 223 Per Line Setup Windows Line 1 and 2 20 6 0 Rem...

Page 3: ... IP 223 Remote Adapter Panel panel to an RTS Intercom System This interface provides PTT Push To Talk control and audio connections from most LMRs Land Mobile Radio to the operator keypanels All Telex Radio Dispatch reference documents are available at http www telex com Downloads IP 223 to RTS Intercom Products ...

Page 4: ... Adapter Panel NOTE RTS documents are available at http www rtsintercoms com manuals php REFERENCE For more information see the appropriate technical manual ADAM CS System Installation Guide P N 9330 7517 000 ADAM Installation Guide P N 9330 7467 000 Cronus User Manual P N 9350 7770 000 ZEUS ZEUSII User Guide P N 9330 7634 000 ZEUSIII User Manual P N 9350 7843 000 FIGURE 1 RTS Matrix to IP 223 Cab...

Page 5: ... O Based on COR Carrier Operated Relay or LAM Line Activity Monitor the IP 223 passes this audio to the IP 223 s Line 2 and out to the RTS Intercom System for playback at keypanels PTT commands at the keypanel generate a relay closure that activates the COR logic at the IP 223 The IP 223 then accepts audio on its Line 2 input The crosspatch transfers the audio from Line 2 to Line 1 and a relay clo...

Page 6: ...do the following 1 Click Multicast Address Setup 2 From Line 1 s Line Type drop down menu select Local Mode 3 From Line 2 s Line Type drop down menu select Local Mode 4 Click Submit The Multicast Address Setup configuration is temporarily saved 5 Click Save to EEPROM The EEPROM window appears 6 Click Save Parameters All configurations are permanently saved to the IP 223 console FIGURE 3 Multicast ...

Page 7: ... configuration is temporarily saved 4 Click Save to EEPROM The EEPROM window appears 5 Click Save Parameters All configurations are permanently saved to the IP 223 console 3 1 3 Per Line Setup Window Line 1 The Per Line Setup window is used to configure per line setup Line 1 configuration depends on the type of radio interface REFERENCE For more information about special configuration requirements...

Page 8: ...osure do the following 1 Click Per Line Setup The Per Line Setup window appears 2 Click Line Select 2 The Per Line Setup window for Line 2 appears 3 Select the COR Enabled check box on Line 2 s Per Line Setup window The RTS supplied relay is enabled 4 Click Submit The Per Line Setup configuration is temporarily saved 5 Click Save to EEPROM The EEPROM window appears 6 Click Save Parameters All conf...

Page 9: ...ed on LAM levels the IP 223 passes the audio to Line 2 and out to the RTS Intercom System for playback at keypanels PTT commands at the keypanel generate a relay closure that activates the COR logic at the IP 223 The IP 223 then accepts audio on its Line 2 input The crosspatch transfers the audio from Line 2 to Line 1 and a relay closure is activated to key the iDEN Audio is passed from the IP 223...

Page 10: ... window appears 2 From Line 1 s Line Type drop down menu select iDEN Radio 3 From Line 2 s Line Type drop down menu select Local Mode 4 Click Submit The Multicast Address configuration is temporarily saved 5 Click Save to EEPROM The EEPROM window appears 6 Click Save Parameters All configurations are permanently saved to the IP 223 console NOTE No other Multicast Address Setup window changes are r...

Page 11: ...k Save to EEPROM The EEPROM window appears 5 Click Save Parameters All configurations are permanently saved to the IP 223 console 4 1 3 Per Line Setup Window Line 1 The Per Line Setup window for Line 1 shown in Figure 8 is used to setup LAM and activate options such as F1 Last Call Full Duplex and RxACG The recommended LAM level is 25dB However the optimum level may vary depending on the terminal ...

Page 12: ...Intercom Products 12 AN DISPATCH 035 REFERENCE For more information see the NI 223 Technical Manual P N 804165 for jumper settings and alignment procedures for Line 1 FIGURE 8 Per Line Setup Window iDEN Radio Line 1 ...

Page 13: ...k box 4 Click Submit The configuration is temporarily saved 5 Click Save to EEPROM The EEPROM window appears 6 Click Save Parameters All configurations are permanently saved to the IP 223 console To configure PTT with VOX for an iDEN radio connection do the following 1 Click Per Line Setup The Per Line Setup window appears 2 Click Line Select 2 The Per Line Setup window for line 2 appears 3 In the...

Page 14: ...IP 223 to RTS Intercom Products 14 AN DISPATCH 035 FIGURE 9 Per Line Setup Window Local Mode Line 2 ...

Page 15: ...t the local IP 223 line I O are passed across the IP network to the remote IP 223 The remote IP 223 keys the radio device and passes audio for transmission 5 1 Local IP 223 Setup The locally connected IP 223 must to be configured for local mode operation on both lines The Line Type and jumper settings should be appropriately configured for the device being connected The following example uses an i...

Page 16: ... Setup configuration is temporarily saved 4 Click Save to EEPROM The EEPROM window appears 5 Click Save Parameters All configurations are permanently saved to the IP 223 console To configure a multicast system do the following 1 From the local IP 223 configuration webpage click Multicast Address Setup The Multicast Address Setup window appears 2 Enter the same Multicast Address in Line 1 s Rx and ...

Page 17: ...t number for Line 1 for example 1054 Line 1 s Tx Port field enter a Tx port number for Line 1 for example 1072 Line 2 s Rx Port field enter an Rx port number for Line 2 for example 1055 Line 2 s Tx Port field enter a Tx port number for Line 2 for example 1073 NOTE The range for the Tx and Rx port number fields is 1054 to 65535 FIGURE 11 Multicast Address Setup Window WAN LAN Configuration Local IP...

Page 18: ...ess Setup configuration is temporarily saved 5 Click Save to EEPROM The EEPROM window appears 6 Click Save Parameters All configurations are permanently saved to the IP 223 console To configure PTT with VOX for a WAN LAN system do the following 1 In the LAM Level dB field enter the level in dB 2 In the LAM Time field enter three 3 seconds 3 Click Submit The Multicast Address Setup configuration is...

Page 19: ...ow appears 2 Enter the static IP Address of the local IP 223 in Line 1 s Rx and Tx Mcast Address fields Line 2 s Rx and Tx Mcast Address fields 3 Click Submit The Multicast Address Setup configuration is temporarily saved 4 Click Save to EEPROM The EEPROM window appears 5 Click Save Parameters All configurations are permanently saved to the IP 223 console To configure a multicast system do the fol...

Page 20: ...r Line 2 for example 1073 4 Line 2 s Tx Port field enter the same port number as the local IP 223 s Rx port number for Line 2 for example 1055 5 Click Save to EEPROM The EEPROM window appears 6 Click Save Parameters All configurations are permanently saved to the IP 223 console NOTE The range for the Rx Port field and Tx Port field is 1054 to 65535 5 2 2 Remote IP 223 Per Line Setup Windows Line 1...

Page 21: ...om the LMR is connected to the I O of the DSP 223 and amplified down the 2 or 4 wire line to Line 1 I O of the IP 223 The IP 223 based on LAM passes audio to Line 2 of the IP 223 and out to the RTS Intercom System for playback at keypanels PTT commands on a keypanel generate a relay closure and audio is inserted on Line 2 of the IP 223 COR and audio inputs This creates a PTT tone generation sent o...

Page 22: ...ne 1 select Tone Mode 3 From the Line Type drop down menu for Line 2 select Local Mode 4 Click CRP Setup The Crosspatch Setup window appears 5 Select the Enable Line Line check box full stop 6 Click Submit The Multicast Address Setup configuration is temporarily saved 7 Click Save to EEPROM The EEPROM window appears 8 Click Save Parameters All configurations are permanently saved to the IP 223 con...

Page 23: ...Line 1 The Per Line Setup window shown in Figure 16 require no changes although various fields and options can be set based on the line type being configured REFERENCE For more information see the IP 223 Technical Manual P N 803641 FIGURE 16 Per Line Setup Window Tone Mode Line 1 ...

Page 24: ...he COR Enabled check box must be selected on Line 2 s Per Line Setup window An example is shown in Figure 17 To configure an RTS supplied relay closure for a remote tone control system do the following 1 Click Per Line Setup The Per Line Setup window appears 2 Select the COR Enabled check box See Figure 17 3 Click Submit The Per Line Setup configurations are temporarily saved FIGURE 17 Per Line Se...

Page 25: ...e LAM Level dB field enter the level in dB 2 In the LAM Time field enter three 3 seconds 3 Click Submit The Per Line Setup configurations are temporarily saved 4 Click Save to EEPROM The EEPROM window appears 5 Click Save Parameters All configurations are permanently saved to the IP 223 console NOTE The recommended LAM level is 20dB to 25dB FIGURE 18 Per Line Setup Window Local Mode Line 2 ...

Page 26: ... AN DISPATCH 001 Kenwood TK x180 100 301956000 AN DISPATCH 001 Kenwood TK 57 5810 100 301956000 AN DISPATCH 001 Kenwood TK 6110 1 AN DISPATCH 023 Kenwood TKR x40 32 Kenwood TKR x50 16 AN DISPATCH 021 M A Com Ericsson GE M7100 1 AN DISPATCH 032 Midland Base Tech II 16 Motorola Astro Spectra 1 Motorola CDM PRO 16 301969000 AN DISPATCH 009 Motorola DIU 3000 1 Motorola MCS2000 1 AN DISPATCH 020 Motoro...

Page 27: ...9 Kenwood TK220 320 240 248 250 350 260 270 TH91A AT E TH25A 400100043 Kenwood TK280 380 290 480 481 400100150 M A COM Ericsson GE MRK Prism 400100139 M A COM Ericsson GE KPC 400100143 M A COM Ericsson GE LPE 400100154 M A COM Ericsson GE Jaguar 400100160 Motorola SABRE MX1000 ASTRO 400100069 Motorola HT750 1250 400100152 Motorola EX500 400100162 Motorola GP300 GTx P110 HT1225 P1225 SP50 GP1250 LT...

Page 28: ...IP 223 to RTS Intercom Products 28 AN DISPATCH 035 ...

Page 29: ...ons or comments Contact technical support with suggestions or comments concerning this application note Technical Support Email TelexDispatchtechsupport us bosch com Fax 1 402 467 3279 Phone 1 800 898 6723 Bosch Security Systems Inc 8601 East Cornhusker Highway Lincoln Nebraska 68507 Phone 800 752 7560 Fax 402 467 3279 Email Telexdispatch us bosch com Web www telex com ...

Page 30: ......

Reviews: