IP-223 to RTS Intercom Products
AN-DISPATCH-035
13
4.1.4
Per Line Setup Window Line 2
The
Per Line Setup
window for Line 2, shown in Figure 9, is used to set up COR or
VOX triggering and audio levels. Depending on the connection to the RTS
equipment, VOX or COR triggering may be used.
To
configure an RTS supplied relay closure for an iDEN radio connection
, do
the following:
1. Click
Per Line Setup
.
The Per Line Setup window appears.
2. Click
Line Select 2
.
The Per Line Setup window for Line 2 appears.
3. Select the
COR Enabled
check box.
4. Click
Submit
.
The configuration is temporarily saved.
5. Click
Save to EEPROM
.
The EEPROM window appears.
6. Click
Save Parameters
.
All configurations are permanently saved to the IP-223 console.
To
configure PTT with VOX for an iDEN radio connection
, do the following:
1. Click
Per Line Setup
.
The Per Line Setup window appears.
2. Click
Line Select 2
.
The Per Line Setup window for line 2 appears.
3. In the LAM Level dB field, enter the
level
in dB.
4. In the LAM Time field, enter
three (3) seconds
.
5. Click
Submit
.
The configuration is temporarily saved.
6. Click
Save to EEPROM
.
The EEPROM window appears.
7. Click
Save Parameters
.
All configurations are permanently saved to the IP-223 console.
NOTE: