background image

EN

w w w . t e l e v e s . c o m

DVB Meter / Analyser  

with digital processing

Refs. 593601, 593602, 593603, 593604, 593661

593621, 593622, 593624

Instruction Manual

EN

Summary of Contents for H30 CRYSTAL

Page 1: ...EN w w w t e l e v e s c o m DVB Meter Analyser with digital processing Refs 593601 593602 593603 593604 593661 593621 593622 593624 Instruction Manual EN ...

Page 2: ......

Page 3: ...5 6 Dish Alignment 16 7 Satellite Test 17 8 Learning Plan 17 9 Constellation 18 10 Echoes 19 11 Video Camera opt 593236 20 12 Wi Fi Scan opt 593250 20 13 IPTV opt 593251 21 14 Setup 24 Firmware Update 25 Web Application 26 1 Measurements 26 2 Plans 27 3 SCR 28 4 Quality Profiles 28 5 Multiscreen 29 6 Clone 29 7 Update 29 Mobile Devices App 30 1 Connection between the App and the H30Crystal 30 2 Fe...

Page 4: ...nds or compression Electrical Supply Grounding and Surge Protection Ensure that all local or national electrical codes are followed Power Lines Always use caution and avoid operating this or any connected equipment near uninsulated power lines or any other hazards Servicing There are no user serviceable parts except the battery Do not attempt to service this product or remove covers other than the...

Page 5: ...asurements needed in today s fulfilment environment Key Features User friendly handheld DVB meter Complete portfolio of Analog Digital measurements with easy to read pass fail indicators Quick and easy to use interface with features such as Channel measurements System Scans Constellation Diagram Spectrum Analyzer Echoes Datalogger and more Rugged light weight fully automatic fast and accurate Easy...

Page 6: ...ad Datalogs and software updates Storage 400 MB internal for measurements Power up time 10 seconds References and options Non Selective Optical Fibre References 593601 H30Crystal OF S S2 T 593602 H30Crystal OF S S2 T T2 593603 H30Crystal OF S S2 C 593604 H30Crystal OF S S2 T T2 C 593661 H30Crystal OF S S2 ISDB T TB Selective Optical Fibre References 593621 H30Crystal Selective OF S S2 T 593622 H30...

Page 7: ...G image Modulations 16QAM 32QAM 64QAM 128QAM and 256QAM Power 45 110dBuV 25 120dBuV opt 593235 CBER 1 2E 2 1 0E 8 MER Up to 38dB C N Up to 40dB Constellation Digital Measurements DVB S MPEG image Power 45 110dBuV 25 120dBuV opt 593235 CBER 9 9E 2 1 0E 6 VBER 1 0E 4 1 0E 8 MER Up to 20dB C N Up to 20dB Constellation Digital Measurements DVB S2 MPEG image Modulations QPSK 8PSK Power 45 110dBuV 25 12...

Page 8: ...ld for approximately 3 seconds 2 Back button Return to the previous menuorcloseaparameterentrywindow 3 Home button Return to the main menu 4 Navigation buttons Used to scroll through options 5 OK Button To confirm selection 6 Setup button Parameter window for the current function 7 LED Powering Indicates if the equipment is powering an external load 8 LED Charging Battery LED flashes while the bat...

Page 9: ... 3 hour charge will provide approximately a 75 charge The charge management system will detect various conditions preventing charging such as a battery that is over a safe temperature About battery Important If the meter detects a shortcircuit or over consumption and it is not connected to the power supply it automatically shuts down To turn it on again it is necessary that it is connected to the ...

Page 10: ...the meter Carefully remove the connector from the power board and then remove the battery 3 sec OFF 3 sec OFF Place the new battery and then connect it to the power board Replace the back cover of the meter Make sure that the cable is not trapped between the two covers Replace the screws of the back cover 3 sec OFF 3 sec OFF 3 sec OFF ...

Page 11: ... the PIN in your H30Crystal 2 3 If the PIN is OK you have finished the registra tion process NOTE Options 593234 dCSS and 593235 Extended terrestrial input level range will be activated automatically in your H30Crystal whenever you register it within 30 days after you turn it on for the first time Product operation 1 Optical Attenuation Measures the optical attenuation over the three wavelengths u...

Page 12: ...dels each wavelength must be calibrated separately Reset calibration both Selective and Non Selective models Resets the calibration Save datalog Saves the current scan measurements You can see the datalogs using the remote control application 2 Channel Info Analog and digital channels are very different in terms of signal content and power distribution and thus require the advanced SLM techniques ...

Page 13: ...uto Analog Digital Save datalog Saves the current scan measurements You can see the datalogs using the remote control application 3 Spectrum Real time processing speeds ensure capture of any fast intermittent plant impairments Due to the accuracy and level of detail provided by this spectrum analyzer the H30Crystal is the ideal tool for identifying and locating noise interference ingress and other...

Page 14: ...s necessary to increase the reference level to get a more accurate adjustment This is a useful feature to point antennas without having to look at the display Span 5MHz 10MHz20MHz 50MHz 100MHz 200MHz 500MHz Full Set the span of the spectrum To easily change the span use the OK Button to decrease the span and the Back Button to increase the span Ref Level Select the reference level of the spectrum ...

Page 15: ... SCR only satellite band Selects the SCR parameters multiswitch standard and slots When a slot is enabled for example slot 3 freq 1210MHz the meter will tune into the slot frequency 1210MHz and will set the slot with the meter parameters frequency band powering and DiSEqC In addition a SCR icon will be shown in the bar at the top SCR3 to indicate that the slot is enabled While the slot is enabled ...

Page 16: ...measurement is the quotient between the current LKM value and the maximum one When the performance indicator is green the dish is aligned 6 1 Main window Below is a capture of the Dish Alignment window with a brief explanation of its features 6 2 Setup Press to change the Dish Alignment options Sat Plan Allows the user to select the satellite plan he wants to align the dish to Beep ON OFF If ON is...

Page 17: ...nge using 7 2 Setup Press to change the Satellite Test options Powering Select the powering of the LNB if needed DiSEqC Select the SAT of the DiSEqC command SCR only satellite band Selects the SCR parameters multiswitch standard and slots When a slot is enabled for example slot 3 freq 1210MHz the meter will tune into the slot frequency 1210MHz and will set the slot with the meter parameters freque...

Page 18: ...evel and V A For digital channels the measurements are power and C N The analog channels will have an extra smaller white bar indicating the level of the audio carrier 8 1 Main window Below is a capture of a Learning Plan window with a brief explanation of its features List of measurements with pass fail indicators Bar graph representing found channels Color according to checkmarks Indicates that ...

Page 19: ...OFF for the full constellation Tuning Channel Frequency Savedatalog Savesthecurrentconstellation measurements You can see the datalogs using the remote control application 10 Echoes It is important to check that no echoes can cause problems in the reception of DVB T and DVB T2 signals This feature allows you to visualize the echoes of the received signal helping the installer to minimize them as m...

Page 20: ...1 Main window Below is a capture of a Camera window 12 Wi Fi Scan opt 593250 Analyzes the Wi Fi band and automatically detects all the Wi Fi networks as well as their names and the power of the access point signal There are two different screens to display the information List and Map 12 1 List view You can go through the list using and select one of the Wi Fi networks to display it separately If ...

Page 21: ...3 1 1 2 Setup Press to change IPTV Measurements options List of measurements Selected channel data Selected channel 12 2 Map view 12 3 Setup Press to change the Wi Fi Scan options Band Terrestrial Satellite Mode Selects between Map or List View Sort Only in List View mode Allows to select how to sort the Wi Fi list name level or channels Screen capture Captures the current screen and saves it as a...

Page 22: ...TV Services window with a brief explanation of its feature Channels Allows to change the selected IPTV channel Save Datalog Saves the current IPTV measurements You can see the datalogs using the remote control application 13 1 2 MPEG Using this function you can see the MPEG image 13 1 2 1 Main Window Below is a capture of a IPTV MPEG window with a brief explanation of its feature If you press the ...

Page 23: ...ral satellite plans from multiple Zones Europe Asia Atlantic and America and customers plans Sat Freq IF real Freq Sat LNB Universal C Band Other If Other is selected you must enter the Once you have selected a service press OK to see all the parameters and bitrates of the audio and video List of services and bitrates Press OK to select a service Selected channel parameters Selected channel Video ...

Page 24: ...elected the user must set the DNS Gateway Wi Fi Allows to connect the H30 to a Wi Fi network Wi Fi On Off Mode AP Access Point Client Scan When Wi Fi is turned on and the selected mode is Client it shows a list of all the found Wi Fi networks As you can see in the image above the list shows the name of the Wi Fi networks and indicates if the network is open or restricted as well as the protection ...

Page 25: ...ew firmware version The icon with the arrows indicates that there is a new firmware version Web Application First of all connect your H30Crystal to the network using the Ethernet connector or theWi Fi interface Then you must find out the IP of your H30Crystal see section 11 Setup Network Wi Fi Then type your H30Crystal IP in the address bar of your web browser and press Enter Then you can see the ...

Page 26: ...og name Channel measurements Filter according to channel type 2 Plans In this window you can see all the channel plans of your H30Crystal 2 1 Terrestrial Satellite and Custom Channel Plans The channel plans are grouped in three categories Terrestrial Satellite and Custom The Terrestrial and Satellite channel plans are the standard channel plans of the corresponding band These plans can be removed ...

Page 27: ...n You can create a new channel plan from an existing one by clicking on the corresponding button Or you can start from scratch by clicking on the New custom plan button 2 2 Plans repository The application also allows to configure the channel plans according to the geographic area you will use the meter When you turn the meter on for the first time you must select the language and then you must se...

Page 28: ...licate multiswitch Save multiswitch Type to edit Duplicate profile Display to see all the values Save the profile in the meter Delete profile Duplicate profile 5 Multiscreen Using this feature you can control your H30Crystal remotely For this to work it is necessary that the H30Crystal and the computer are connected to the same LAN To access to this feature you must enter the password admin in the...

Page 29: ...ystal is connected to the internet it will detect new purchased licenses automatically when you turn it on and will install them automatically But if you get the licenses from your distributor you can install them in your device by clicking on Add license Click to display the function Mobile Devices App 1 Connection between the App and the H30Crystal You only need to have turn your H30Crystal on a...

Page 30: ...fo the user can see the following screen 2 Features Once your tablet and your H30Crystal are con nected you can operate with the App using the following features 2 1 Loggers This window shows the Logs saved in your H30Crystal When you tap on one of these logs to select it you will see all the measurements at the bottom of the screen When the H30Crystal is connected the icon is green Tap to select ...

Page 31: ...on to display the keyboard will be displayed Use these buttons as if they were the device If the selected function is MPEG the video is shown next to the information window Note1 HEVC videos only can be displayed on tablets that support this standard Note2 Videos are supported up to 1080p Note3 If the user selects the Video Camera function while using the multiscreen feature the Tap on the arrow b...

Page 32: ... your H30Crystal as well as add new user channel plans and edit them The standard channel plans can not be edited User defined Plans Standard Plans The standard plans can be cloned When the user does this a new channel plan is added to the User channel plans list Enter the new user defined channel plan name and it will be automatically uploaded to your H30Crystal Clone channel plan Type the new ch...

Page 33: ...ator with the web page of your H30Crystal and points directly to the SCR section See section 3 SCR of the Web Appli cation 2 3 3 Quality Profile This function opens a web navigator with the web page of your H30Crystal and points directly to the Quality Profile section See section 4 Quality Profi les of the Web Application 2 3 4 IPTV With this function the user can create and edit IPTV channel plan...

Page 34: ...ing this function of the App the user can see the App information as well as the H30Crystal whenever it is connected to the App 2 4 2 Manual Using this funtions the user manual will be displayed in the App 2 4 3 Register The user can register his H30Crystal using this function The first time that you turn your H30Crystal on it will ask you to register it If you register your H30Crystal within 30 d...

Page 35: ...ve the registration process for a moment and follow the instructions explained in the section 1 Connection between the App and the H30Crystal Then turn your H30Crystal OFF and then ON again to start the Register process Select Settings Register menu in the App Now you must disconnect your mobile device from your H30Crystal and connect it to the internet Then it will be open a web browser with the ...

Page 36: ...witch off BAD POWER Unplug power source This message appears when the meter is connected to an external power source that does not supply it the right power Please use only the power source provided with the H30Crystal SHORT CIRCUIT Check installation This message appears when the meter detects a short circuit at the RF input It is recommended to check the installation to find out why the short ci...

Page 37: ...to ensure proper use and attempt to RESET the unit to clear any problems Repair service Do not return the unit without first contacting Televes Technical Support If the unit needs to be returned Televes will arrange for free shipping The unit will need to be appropriately packed for shipping In compliance with IATA Regulations when using our shipping service follow these instructions Label the pac...

Page 38: ...N OF CONFORMITY DECLARAÇÃO DE CONFORMIDADE DECLARATION DE CONFORMITE DICHIARAZIONE DI CONFORMITÀ DEKLARACJA ZGODNOŚCI KONFORMITÄTSERKLÄRUNG ΠΙΣΤΟΠΟΙΗΤΙΚΟ ΣΥΜΜΟΡΦΩΣΗΣ FÖRSÄKRAN OM ÖVERENSSTÄMMELSE ДЕКЛАРАЦИЯ СООТВЕТСТВИЯ نايب ةقباطملا www doc televes com ...

Page 39: ......

Page 40: ...593601 593602 593603 593604 593661 593621 593622 593624_1 00_EN ...

Reviews: