Server Installation and Maintenance
Installing the Server
19
Lightspeed G-Series Guide
Installing the Server in the Rack
When selecting a position in a rack to place the server, be sure to allow a minimum of
30 inches of clearance at the back of the server for sufficient cooling airflow and
servicing.
To install the server, follow this procedure:
Slide the inner rail extensions forward into the front of the outer rails.
Support the chassis and align the back of the chassis with the front of the rails.
Push the chassis backward, sliding it into the rack rails, until the chassis clicks into the
locked position.
CAUTION:
To prevent the server from falling and becoming damaged, be sure it is
securely in the rack before you remove support.
If you need to remove the server from the rack, press the outer rail latch shown in the
figure to release the chassis.
Slide the chassis forward off the outer rails and out of the chassis.