![TeleSite QuickSilver DV202S Installation & Operation Manual Download Page 37](http://html1.mh-extra.com/html/telesite/quicksilver-dv202s/quicksilver-dv202s_installation-and-operation-manual_1082174037.webp)
TX001-00-00 Rev 101 QuickSilver DV202S Video Transmitter
Technical Information
••••
29
Technical Information
ELECTRICAL
Applies to DV202S Transmitter and CRU.
Input Voltage:
DV202S (120 VAC): Wall transformer provided with +12, -12 and
+5 VDC accepting 120 VAC.
DV202S (230 VAC): Wall transformer provided with +12, -12 and
+5 VDC accepting 230 VAC.
CRU (120 VAC): Wall transformer provided with 12 VDC out and
120 VAC in.
CRU (230 VAC): Wall transformer provided with12 VDC out and
230 VAC in.
Current Drain:
DV202S: 0.9 A nominal.
CRU: 1.0 A nominal.
Power Consumption:
DV202S: 24 W nominal.
CRU: 12 W nominal.
Heat Equivalent:
DV202S: 1.4 btu/min ( 0.35 cal/min).
CRU: 0.7 btu/min ( 0.18 cal/min).
Note: These figures represent the conversion of 100% of the
electrical energy to heat. Actual percentage of the heat
generated will be less and will vary from product to product.
These figures are provided as an aid in determining the
extent of cooling required for an installation.
Connector Types/Quantities:
(DV202S Transmitter)
Video inputs: 6 BNC-F.
Video output: 1 BNC-F.
Power: 1 DIN type socket.
Serial Data: 2 DB9-M.
Data: 1 DB25-M.
Audio input: 1 1/8 inch phono type socket.
Audio output: 1 1/8 inch phono type socket.
Relay outputs: 2 outputs using 6 Terminal Block screws.
RS-422/485 Data output: 2 Terminal Block screws (A and B).
Alarms: 6 inputs using 8 Terminal Block screws.
(CRU)
Video inputs: 4 BNC-F.
Video output: 1 BNC-F.
Power: 1 Coaxial type socket.
Data: 1 DB25-M.
Alarms: 4 inputs using 8 Terminal Block screws.