5.
Verify the armature and shim(s) are in place prior to securing the solenoid. Align the holes and attach
with two M3-.05 x 6mm flat head cap screws.
C A U T I O N
Do not pull the wires through from the backside of the cartridge base. Doing
so might strip insulation from the wires and short the solenoid drivers.
6.
Push the wires from the front through the notches while taking up the slack from the back of the
cartridge base until all slack is removed from the wires.
7.
Route the wires down the side of the frame, opposite the cam, allowing enough wire with slight slack
when the cartridge is at the cam side of the frame.
8.
Place a wire tie around the frame and wires immediately ahead of the boss for the right side pulley (as
viewed from the top). Place a second wire tie around wires and through the frame’s large rear hole.
9.
Plug the wires into jacks J6 and J7.
10. Install the marking unit into left cover and secure with three flat head screws.
11. Connect the marking unit cable connector J2 to J1 on the limit board.
12. Attach the ground lug.
13. Install the handle mount onto left cover (with radius end of handle toward the back of the marker).
Secure with two M4-0.70 x 16 socket head cap screws.
14. Slide the handle onto the handle mount and tighten the set screw.
15. Install the push button switch assembly (connector end first) through the switch mounting hole.
16. Route the switch wires in and upward through the clearance hole toward the limit board.
17. Connect the switch wires to J2 on the limit board.
18. Secure the switch to the handle with a M3-0.50x3 set screw.
19. Lay the flex snap in the strain relief bushing on the cable assembly in the half-hole in the back of the left
cover with the tab facing down into the half-hole.
20. While holding the bushing in place, lay the right cover on top.
Ensure the push button wires are not pinched between the covers.
21. Secure the right cover with four M3-0.50 x 25 socket head cap screws.
22. Install the impact pin / pin cartridge onto the marking head. (see replacement procedure)
23. Install the standoffs. (see replacement procedure)
Summary of Contents for PINSTAMP TMP4100 Series
Page 2: ......
Page 10: ...TMP4100 Series Installation Maintenance viii 33480D01 DOC This page intentionally left blank...
Page 23: ...TMP4100 Series Installation Maintenance 33480D01 DOC 1 13...
Page 24: ...TMP4100 Series Installation Maintenance 1 14 33480D01 DOC This page intentionally left blank...
Page 25: ...TMP4100 Series Installation Maintenance 33480D01 DOC 1 15...
Page 28: ...TMP4100 Series Installation Maintenance 1 18 33480D01 DOC This page intentionally left blank...
Page 52: ...TMP4100 Series Installation Maintenance 2 24 33480D01 DOC This page intentionally left blank...
Page 54: ...Appendix A A 2 33480D01 DOC This page intentionally left blank...