background image

TELES iGATE FCT User’s Guide

12

Previous Page

Table of Contents

Next Page

Programming Summary  

                  

Table 3: DTMF Programming Summary

Code

Function

Remarks

**1343**#

Enter program-
ming mode

To exit programming mode, hang-
up.

*3210*#

Update Immedi-
ate Dialling.  The 
channel will start 
dialling immedi-
ately after 
receiving this 
number of digits

This is followed by the number of 
digits required for Immediate Dial-
ling and then by #.   Enter “0” to 
disable Immediate Dialing.

*3211*#

Update Inter-
digit Timeout

See “Interdigit Timeout” on 
page 15.

*5351*#

Erase Toll 
Restriction table

See “Toll Restriction” on page 19.

*5470*#

Restore Factory 
Default

See “Restore Factory Default” on 
page 18.

*5580*#

Change Rx/Tx 
audio gain

See “Audio Gain” on page 13.

*6100*#

Enable SIM PIN 
code feature

See “PIN Code Programming” on 
page 16.

*6101*#

Disable SIM PIN 
code

See “PIN Code Programming” on 
page 16.

*6110*#

Change SIM PIN 
code

See “PIN Code Programming” on 
page 16.

*6122*#

Clear Channel 
Lock

See “Clearing a Lock” on page 14.

*6133*#

Call Duration 
Limit

See “Call Duration Limit” on 
page 13.

*6150*#

Erase SMS mail-
box

See “Erase SMS Inbox of the SIM 
card” on page 14.

*8200*#

Enable CLIR

See “Calling Line Identification 
Restriction (CLIR)” on page 14.

*8201*#

Disable CLIR

See “Calling Line Identification 
Restriction (CLIR)” on page 14.

*8600*#

Enable Comfort 
Tone

This activates a short beep that is 
played in place of silence.

*8601*#

Disable Comfort 
Tone

This deactivates the comfort tone.

*8620*#

Enable Mod-
ule’s Dial Tone

Creates a dial tone matching that 
heard in the United States

*8621*#

Disable Mod-
ule’s Dial Tone

Disables the US dial tone

*9190*#

Enable Toll 
Restriction

See “Toll Restriction” on page 19.

*9193*#

Disable Toll 
Restriction

See “Toll Restriction” on page 19.

*9194*#

Add entry to Toll 
Restriction table

See “Toll Restriction” on page 19.

*9195*#

Remove entry 
from Toll Restric-
tion table

See “Toll Restriction” on page 19.

Table 3: DTMF Programming Summary

Summary of Contents for iGATE FCT

Page 1: ...Table of Contents Next Page TELES iGATE FCT User s Manual...

Page 2: ...Version Information and Disclaimer iGATE FCT carries CE Certification This manual is applicable to TELES iGATE FCT with soft ware versions 0218 or higher These apply to units with part number Q11 1110...

Page 3: ...mmary 12 Features 13 Audio Gain 13 Call Duration Limit 13 Calling Line Identification Restriction CLIR 14 Clearing a Lock 14 Erase SMS Inbox of the SIM card 14 Immediate Dialing 15 Interdigit Timeout...

Page 4: ...T User s Guide 1 Previous Page Table of Contents Next Page Chapter 1 Introduction This section includes Overview on page 2 Product Components ID on page 2 Contents of Package on page 3 Safety Precauti...

Page 5: ...is transparent The PABX recognizes iGATE FCT as a trunk interface and the routing is done in the PABX itself In a PABX that does not support LCR the user must select the proper trunk for the call The...

Page 6: ...ety Precautions To avoid injury and prevent equipment damage observe the following safety precautions Do not ship equipment unless it is properly packed in its original wrapping and shipping container...

Page 7: ...e 4 Previous Page Table of Contents Next Page Chapter 2 Getting Started This section includes Installing the Unit on page 5 Initial Start up and LEDs on page 7 Testing the Installation on page 8 Instr...

Page 8: ...ferred 6 Select a location for the antenna The location must meet the following criteria at least one meter away from the unit with room for the metal plate with room for the antenna to stand in an up...

Page 9: ...Line Connector Pin Layout Warning Do not use the reserved pins Note The line can use either pins 3 and 4 or pins 2 and 5 12 Ensure that the PABX is properly configured For details regarding the progr...

Page 10: ...t up and LEDs Initial Start up and LEDs After the power cable is attached the POWER LED should be illuminated If it is not ensure that the cable is properly connected to the unit and to the AC mains D...

Page 11: ...LED is red Note Ensure that the dialed number does not conflict with the toll restriction rules if activated Checking Incoming Calls 1 Using a second phone dial the phone number of the SIM card insert...

Page 12: ...ial If Toll Restriction is active in a PABX without LCR some destinations will not be reachable because the call will be too expensive Use the proper prefix If Call Duration Limit is active calls long...

Page 13: ...T User s Guide 10 Previous Page Table of Contents Next Page Chapter 3 Programming This section includes How to Program on page 11 Programming Summary on page 12 Features on page 13 Factory Default Val...

Page 14: ...tion confirmation tone 2 short beeps indicate rejection or inability to perform the command rejection tone 3 Enter parameters using the DTMF tones We recom mended that you check the function of every...

Page 15: ...g on page 16 6110 Change SIM PIN code See PIN Code Programming on page 16 6122 Clear Channel Lock See Clearing a Lock on page 14 6133 Call Duration Limit See Call Duration Limit on page 13 6150 Erase...

Page 16: ...igits The unit emits the confirmation tone Wait until the call is answered 4 Dial either 70 for Tx gain 71 for Rx gain The unit emits the confirmation tone 5 Adjust the volume by pressing the keys on...

Page 17: ...arty The unit emits the confirmation tone Clearing a Lock Lock occurs after an unsuccessful attempt to change the PIN code The unit will not perform any command rele vant to a PIN code change until th...

Page 18: ...r example 9 shorter numbers are sent to the cellular network after the preset delay or after pressing the sign 1 Dial 1343 The unit enters the programming mode and emits the confirmation tone 2 Dial 3...

Page 19: ...is wrong the unit locks itself ceases functioning and the STATUS LED blinks See Clearing a Lock on page 14 Note The unit locks in order to prevent the SIM card from locking SIM cards lock after 3 fai...

Page 20: ...urrent PIN code of the unit 1 Reset the unit to the factory default setting See Restore Factory Default on page 18 2 Set the SIM card s PIN to 1234 To program a SIM card place it in a mobile phone and...

Page 21: ...and recon nect it Set Pulse Drop Signaling Method If the PABX trunk connected to the unit supports Pulse Drop use this command to set the unit to Pulse Drop sig nalling mode 1 Dial 1343 The unit ente...

Page 22: ...g those starting with the sign are never blocked This ensures that emergency and special service calls are placed The list of allowed prefixes can include up to 10 entries The minimum length of a pref...

Page 23: ...ds Table 5 Toll Restriction Commands Command Result 9193 Disables the Toll Restriction fea ture This does not erase the entries in the table 9195 fol lowed by a prefix followed by the sign This delete...

Page 24: ...TELES iGATE FCT User s Guide 21 Previous Page Table of Contents Next Page Chapter 4 SMS This section includes SMS Commands Overview on page 22 GET Command Table on page 22 SET Command Table on page 23...

Page 25: ...ng programming feature Note The speed SMS messages are delivered is dependent upon the network There may be a delay GET Command Table Table 6 GET Command Table Command Syntax Command Feature Applicabl...

Page 26: ...ommand Feature Applicable Response Table 7 SET Command Table Command Syntax Command Feature Applicable Response SIG P Set Signalling method to Pulse Drop Line Signal is Pulse Drop XX Where XX is the w...

Page 27: ...User s Guide 24 Previous Page Table of Contents Next Page Chapter 5 Miscellaneous This section includes Call Progress Tones on page 25 LED Indications on page 25 Troubleshooting on page 26 Specificat...

Page 28: ...the LED turns off a few seconds every 15 sec onds of operation During a call the indication is fro zen at that which existed when the call started STATUS Indicates the channel oper ational status On T...

Page 29: ...Try using another phone 6 Dial tone does not stop Dial tone continues after dialling first digit Use a different phone Reset the unit reconnect the power supply 7 Can not connect to a destina tion Th...

Page 30: ...pin 2 3 TIP pin 4 5 RING Data Port Specifications Interface port RS232 Protocol AT Command Compatible GSM Channel Specifications Dual band GSM 900 1800Mhz or 850 1900MHz Standards Type Approval CE mar...