cellular network.  You may create several groups, 
serving several networks.

c. Determine if the PABX does or does not support 

Least Cost Routing (LCR).

On PABX's supporting LCR, set the PABX 
routing tables to route the calls to the trunk 
groups.  This is done by selecting the cellular 
prefixes to direct the routing.  Calls that should 
not be made on the iGATE FCT can be 
blocked by using the Toll Restriction feature 
(see p. 19).  The PABX will automatically route 
calls to the iGATE FCT. 

On PABX's that do not support LCR, ensure 
users know how to select the right trunk for the 
cellular calls (see “Instructions for Users” on 
page 9).  After making the selection, users will 
hear a second dial tone, this one emitted by 
the iGATE FCT.

13. Connect the power cable.  

14. Continue with the next section, entitled “Initial Start-up 

and LEDs”.

Initial Start-up and LEDs

After the power cable is attached, the POWER LED 
should be illuminated.  If it is not, ensure that the cable is 
properly connected to the unit and to the AC mains.

During the first seconds, the STATUS LED blinks.  This 
indicates that the unit is initializing.  Once the SIM card is 
registered and operational, the STATUS LED stops 
blinking.  In certain cases, the LED may continue to blink.  
This is normal and reasons appear later in this document.

Verify that the RCPT LVL LED is green.  This indicates a 
high reception level.  (Reception levels are described in 
Table 2.)  To improve the reception level, move the 
antennas to a different location with a better reception 
and/or place the antennas on a metal plate no smaller 
than 30 x 30cm.  If the reception level is still not satisfac-
tory, contact Technical Support.

                    

Table 2: Reception Level Indications

RCPT LED

Reception Level

Green

High reception

-75dBm to - 51dBm

Orange

Medium reception

-87dBm to -77dBm

Red

Low reception

-101dBm to -89dBm

Off

Very low reception or 
no reception at all

-113dBm to -103dBm

Summary of Contents for iGATE FCT

Page 1: ...Table of Contents Next Page TELES iGATE FCT User s Manual...

Page 2: ...Version Information and Disclaimer iGATE FCT carries CE Certification This manual is applicable to TELES iGATE FCT with soft ware versions 0218 or higher These apply to units with part number Q11 1110...

Page 3: ...mmary 12 Features 13 Audio Gain 13 Call Duration Limit 13 Calling Line Identification Restriction CLIR 14 Clearing a Lock 14 Erase SMS Inbox of the SIM card 14 Immediate Dialing 15 Interdigit Timeout...

Page 4: ...T User s Guide 1 Previous Page Table of Contents Next Page Chapter 1 Introduction This section includes Overview on page 2 Product Components ID on page 2 Contents of Package on page 3 Safety Precauti...

Page 5: ...is transparent The PABX recognizes iGATE FCT as a trunk interface and the routing is done in the PABX itself In a PABX that does not support LCR the user must select the proper trunk for the call The...

Page 6: ...ety Precautions To avoid injury and prevent equipment damage observe the following safety precautions Do not ship equipment unless it is properly packed in its original wrapping and shipping container...

Page 7: ...e 4 Previous Page Table of Contents Next Page Chapter 2 Getting Started This section includes Installing the Unit on page 5 Initial Start up and LEDs on page 7 Testing the Installation on page 8 Instr...

Page 8: ...ferred 6 Select a location for the antenna The location must meet the following criteria at least one meter away from the unit with room for the metal plate with room for the antenna to stand in an up...

Page 9: ...Line Connector Pin Layout Warning Do not use the reserved pins Note The line can use either pins 3 and 4 or pins 2 and 5 12 Ensure that the PABX is properly configured For details regarding the progr...

Page 10: ...t up and LEDs Initial Start up and LEDs After the power cable is attached the POWER LED should be illuminated If it is not ensure that the cable is properly connected to the unit and to the AC mains D...

Page 11: ...LED is red Note Ensure that the dialed number does not conflict with the toll restriction rules if activated Checking Incoming Calls 1 Using a second phone dial the phone number of the SIM card insert...

Page 12: ...ial If Toll Restriction is active in a PABX without LCR some destinations will not be reachable because the call will be too expensive Use the proper prefix If Call Duration Limit is active calls long...

Page 13: ...T User s Guide 10 Previous Page Table of Contents Next Page Chapter 3 Programming This section includes How to Program on page 11 Programming Summary on page 12 Features on page 13 Factory Default Val...

Page 14: ...tion confirmation tone 2 short beeps indicate rejection or inability to perform the command rejection tone 3 Enter parameters using the DTMF tones We recom mended that you check the function of every...

Page 15: ...g on page 16 6110 Change SIM PIN code See PIN Code Programming on page 16 6122 Clear Channel Lock See Clearing a Lock on page 14 6133 Call Duration Limit See Call Duration Limit on page 13 6150 Erase...

Page 16: ...igits The unit emits the confirmation tone Wait until the call is answered 4 Dial either 70 for Tx gain 71 for Rx gain The unit emits the confirmation tone 5 Adjust the volume by pressing the keys on...

Page 17: ...arty The unit emits the confirmation tone Clearing a Lock Lock occurs after an unsuccessful attempt to change the PIN code The unit will not perform any command rele vant to a PIN code change until th...

Page 18: ...r example 9 shorter numbers are sent to the cellular network after the preset delay or after pressing the sign 1 Dial 1343 The unit enters the programming mode and emits the confirmation tone 2 Dial 3...

Page 19: ...is wrong the unit locks itself ceases functioning and the STATUS LED blinks See Clearing a Lock on page 14 Note The unit locks in order to prevent the SIM card from locking SIM cards lock after 3 fai...

Page 20: ...urrent PIN code of the unit 1 Reset the unit to the factory default setting See Restore Factory Default on page 18 2 Set the SIM card s PIN to 1234 To program a SIM card place it in a mobile phone and...

Page 21: ...and recon nect it Set Pulse Drop Signaling Method If the PABX trunk connected to the unit supports Pulse Drop use this command to set the unit to Pulse Drop sig nalling mode 1 Dial 1343 The unit ente...

Page 22: ...g those starting with the sign are never blocked This ensures that emergency and special service calls are placed The list of allowed prefixes can include up to 10 entries The minimum length of a pref...

Page 23: ...ds Table 5 Toll Restriction Commands Command Result 9193 Disables the Toll Restriction fea ture This does not erase the entries in the table 9195 fol lowed by a prefix followed by the sign This delete...

Page 24: ...TELES iGATE FCT User s Guide 21 Previous Page Table of Contents Next Page Chapter 4 SMS This section includes SMS Commands Overview on page 22 GET Command Table on page 22 SET Command Table on page 23...

Page 25: ...ng programming feature Note The speed SMS messages are delivered is dependent upon the network There may be a delay GET Command Table Table 6 GET Command Table Command Syntax Command Feature Applicabl...

Page 26: ...ommand Feature Applicable Response Table 7 SET Command Table Command Syntax Command Feature Applicable Response SIG P Set Signalling method to Pulse Drop Line Signal is Pulse Drop XX Where XX is the w...

Page 27: ...User s Guide 24 Previous Page Table of Contents Next Page Chapter 5 Miscellaneous This section includes Call Progress Tones on page 25 LED Indications on page 25 Troubleshooting on page 26 Specificat...

Page 28: ...the LED turns off a few seconds every 15 sec onds of operation During a call the indication is fro zen at that which existed when the call started STATUS Indicates the channel oper ational status On T...

Page 29: ...Try using another phone 6 Dial tone does not stop Dial tone continues after dialling first digit Use a different phone Reset the unit reconnect the power supply 7 Can not connect to a destina tion Th...

Page 30: ...pin 2 3 TIP pin 4 5 RING Data Port Specifications Interface port RS232 Protocol AT Command Compatible GSM Channel Specifications Dual band GSM 900 1800Mhz or 850 1900MHz Standards Type Approval CE mar...