Installation
Page 20
same as for standard modems.
Installing and Removing Power Modules
Power modules generate power that is bused to the 16 modem edge
connectors on the recessed power bus. Power modules are available in
AC and DC versions.
AC Power Module
The AC power module is a 2-slot module designed for the RM16M
ACV-R Data Shelf. The RM16M ACV-R Data Shelf can hold a
maximum of one AC power module.
The AC power module consists of:
v
Two transformers (one for slots 1 through 8 and the other for
slots 9 through 16)
v
Two push-button circuit breaker switches on the front panel
v
A red 3.5 Amp light on the front panel
v
A 115 or 230 VAC connector on the back of the module
Table 2-3 lists the connector pin functions on the AC power module.
Table 2-3. Power Connector Pin Functions
Pin Contact
Function
1 and A
2 and B
Plus and minus 12 Volt
Winding
3 and C
12 Volt Common
4 and D
5 and E
5 Volt Winding
6 and F
Chassis Ground
Summary of Contents for RM16M - Versatile Rack Mounting Chassis
Page 1: ...RM16M DCV R RM16M ACV R Installation and Operation Guide TEL 6200508506004 Rev A...
Page 17: ...Page 17 Figure 2 4 Power Terminals Figure 2 5 Example of a Single Power Source Installation...
Page 21: ...Page 21...
Page 27: ...Page 27 J2 J1 J3 Wire Wrap 50 25 25...
Page 28: ...Installation Page 28 NOTES...
Page 30: ...Operation Page 30 front panel The LCD functions are explained in the manual for the modem...
Page 32: ......
Page 34: ...Maintenance Page 34 NOTES...
Page 36: ...Specifications Page 36 NOTES...
Page 38: ...24 Volt Input Shelf Page 38 NOTES...
Page 44: ...Telephone Line Cables Page 44 Figure D 1 Programmable Cable Figure D 2 Permissive Cable...