Section 5 – Programming (Continued)
22
8/2/2004
Setup Bank Programming Screen.
After seleting a Bank, the number of the Bank will
appear at the top of the screen.
The respective screens appear as shown below (the 2-
Speed screen is shown first):
NOTE
IF YOU HAVE AN INTELESMART RECEIVER
FREQUENCY AND ACCESS CODES CAN EASILY
BE DOWN LOADED DIRECTLY INTO YOUR PDA.
E. Downloading Parameters from an InteleSmart
receiver.
Select the Bank you wish to program, cycle the power to
the InteleSmart receiver. Within the first 10 seconds of
the receiver turning ON, point the PDA at the receiver’s
IR port (see receiver manual for location) and tap the
“Rx Setting” button on the PDA. The frequency and
Access Code will be downloaded, then skip the next two
steps.
F. Select a Frequency (Must be inputted for system
to work):
There should be a label either on the receiver or the
transmitter being replaced listing frequency, it should be
a channel number between AK01 to AK20. Find this
number and tap the “Freq” arrow and select that channel
number.
G. Enter the Access Code (Must be inputted for
system to work):
Screen switch operation.
The screen switches are labeled from left to right “A”,
and “B”. They are numbered from left to right 1 to 8.
The darken rectangle to the bottom is “OFF” or “0” the
darken rectangle to the top is “ON” or a “1”. Tapping the
lighten rectangle will cause the switch to toggle.
See Section 5.1. Access Code Programming for details
on access code programming. There should be a label
either on the receiver or the old transmitter showing the
access code, it should be numbered A1 through A8 and
B1 though B8. Find this number and tap the respective
switches on the screen. If you cannot find a label with
access code information, copy directly from the access
code dip switches in your transmitter or receiver, being
careful to match the designation and switch position as
they do vary from model to model.
2-Speed
telePendant Bank
Programming Screen.
System
10K
Freq
AK01
Setup Bank #
A1
Receiver access code
1
0
B1
1
0
S3-1
1
0
Timer
Switch conf.: H,T,B
Main/Aux Aux
only
Save
Cancel
Multibox
Auto Turn Off Active ESTOP
RX Setting
15
3-Speed 10K Pendant and 3-Speed
telePendant Bank
Programming Screen.
Multibox
Active ESTOP
RX Setting
15
Freq
AK01
Setup Bank #
A1
Receiver access code
1
0
B1
1
0
Timer
Save
Cancel
E. Select a
Fre
q
uenc
y
Motor
5
telePendant
Access Code
Programming.
Cancel
System
10K
Freq
AK01
Setup Bank #
A1
Receiver access code
1
0
B1
1
0
Timer
Save
Multibox
Auto Turn Off Active ESTOP
RX Setting
15
S3-1
1
0
Switch conf.: H,T,B
Main/Aux Aux
only
F. Screen switches for
Access Code
Summary of Contents for telePendant
Page 31: ...31 8 2 2004 ...