Section 4 – Operation (Continued)
16
8/2/2004
transmitter is turned ON, after Bank Selection is
made and the ON/OFF indicator will remain
lit until the correct password sequence is entered
with in five seconds. An incorrect password
sequence or failure to enter the sequence in time
shuts the unit OFF. The user is allowed to restart
and try again an unlimited amount of times. The
Bank Password is the same for all four Banks.
WARNING
THIS PASSWORD FUNCTION IS NOT TO BE
USED AS A SECURITY DEVICE. THE PUR-
POSE OF THIS FUNCTION IS TO PREVENT
ACCIDENTAL BANK SWITCHING. THE
BEST FORM OF SECURITY IS ALWAYS TO
LOCKUP THE TRANSMITTER WHEN NOT
IN SERVICE. FAILURE TO FOLLOW THIS
WARNING COULD RESULT IN SERIOUS
INJURY OR DEATH AND DAMAGE TO
EQUIPMENT.
When initially programming the unit the default
password is 6, 5, 4, 3. This password can be
easily changed by the PDA during initial
programming.
A password is a sequence of four pushbutton
entries. These entries are any combination of
inputs from the upper most six buttons on the
right hand side of the
telePendant
transmitter.
On 2- and 3-Speed transmitters the second and
third speed is ignored.
Acceptable sequences could duplicate buttons
numbers such as 2, 2, 6, 6 or 1, 1, 1, 4.
NOTE
ALWAYS REMEMBER TO STORE THE
PASSWORD IN A SECURE LOCATION FOR
ACCESS IF THE PASSWORD IS LOST OR
FORGOTTEN. ONCE THE TRANSMITTER IS
PROGRAMMED THERE IS NO WAY TO DE-
FEAT THE PASSWORD WITHOUT USING A
PDA TO EITHER READ THE PASSWORD
OUT OR REPROGRAM A NEW ONE.
The Bank password can be disabled during
initial programming by the PDA.
WARNING
DISABLING THE PASSWORD FUNCTION
PUTS THE SYSTEM IN ACTIVE BANK
SELECT. THIS ALLOWS THE CRANE
OPERATOR TO SWITCH BETWEEN BANKS
QUICKER. THE OPERATOR IN THIS MODE
MUST BE AWARE AND RESPONSIBLE FOR
ALL POSSIBLE CONTROLLED CRANES.
FAILURE TO FOLLOW THIS WARNING
COULD RESULT IN SERIOUS INJURY OR
DEATH AND DAMAGE TO EQUIPMENT.
telePendant
Time-Out-Timer Function.
The transmitter has a time-out timer and the
default condition is 15 minutes. Upon timing out
the transmitter will send an OFF command to the
receiver if Auto Turn Off is active. The
transmitter time-out-timer function is
programmable in minute increments to up to and
including 15 minutes. After that it is
programmable in five-minute increments up to
and including one hour. Infinite time-out (none)
is also selectable. The time-out-timer measures
the time since the last pushbutton stroke and is
continuously reset by any pushbutton activation.
4-6. Battery Replacement.
telePendant
Battery Replacement.
On the
telePendant
if the yellow battery
indicator light starts to flash replace the
battery at the earliest opportunity. If the light is
on solid replace the battery immediately.
Figure 4-3.
telePendant
Battery Replacement.
Summary of Contents for telePendant