4.0 System
Cables
4.1 Power Cable
Power to the unit is made via interconnect cable CA-PWR-7XLR-XXX to the
7-pin XLR power connector located on the rear of the unit (Note: XXX=Feet).
The other end of interconnect cable connects to the external power supply.
Figure 2 Power Cable CA-PWR-7XLR- XXX
4.2 Serial Data Connection
Communication to the unit is made via serial data cable CA-RS to the 9 pin
serial data connector located on the rear of the unit. The other end of the
cable connects to the control panel. Units configured for RS-232 can have a
maximum distance of 100 feet between the unit and the control panel. Units
configured for RS-422 can have a maximum distance of 4000 feet between the
unit and the control panel. (Note: Units are set to accept either RS-232 or RS-
422 at the factory. See Table 1 for proper DIP switch settings.)
Figure 3 Serial Data Cable