Installation

Location of Control

Choose a mounting location for the control head which will provide comfortable operation of the hand lever, 
unobstructed movement of mechanism arms and a clear path for cables to engine.
1. Allow  adequate  clearance  for  hand  and  lever  swing  (forward  and  reverse  positions).  See  page  13  for  the 

control dimensions and the recommended clearance around and behind the mounting surface.

. Allow adequate clearance under the console or in the gunwale for the cables AND allow a minimum of 36” 

from the cable nest connection with no restraint. When supporting the cables beyond 36”, do not tie or clamp 
tightly.

3. After a suitable location for the control is determined, use the separate mounting template to make the cut-out. 

The templates are supplied with the control (also see mounting dimensions on page 14).

4. Closely follow the instructions provided on the template. Cut and drill the mounting holes required.

 

Measuring the Shift Cable

Measure the cable routing path from the control head connection to the engine connection.

Inboards & Stern Drives

Measure from the control connection -- along an unobstructed cable routing -- to the SHIfT connection.
Round this dimension UP to the next whole foot and order the required cable part number.

(Last two digits of the Teleflex cable number equal the length of the cable in feet.)

NOTE:  To  determine  the  correct  control  assembly  for  inboards  with  hydraulic  transmissions,  you  must 
determine if the Shift Cable “pulls” or “pushes” to go into forward.

To outboard or stern 
drive shift connection

Summary of Contents for MV3-E Series

Page 1: ...MV3 E Series Installation and Operation Manual for Hybrid Engine Controls ISCHMV3E Revision 1 0...

Page 2: ...nt collision grounding boat damage or personal injury When the boat is moving water depth may change too quickly to allow time for you to react Always operate the boat at very slow speeds if you suspe...

Page 3: ...Mount Cabling 7 Shift Cable Connection Engine End 8 Shift Cable Connection Control End 8 Connect Shift to Engine Control 8 Throttle Wiring Harness 9 Installation of the Wiring Harness 9 Preparation of...

Page 4: ...from Neutral by raising the lifter under the ball knob The MV3 E accepts Teleflex Marine 33 style cables Important Safety Notices Teleflex Marine Controls highly recommends the installation and usage...

Page 5: ...gears Neutral Throttle Warm up Button This feature provides a Throttle Only option to operate the engine throttle without going into gear Operation When the Control Hand Lever is in Neutral lift the...

Page 6: ...cation for the control is determined use the separate mounting template to make the cut out The templates are supplied with the control also see mounting dimensions on page 14 4 Closely follow the ins...

Page 7: ...User Manual MV3 E Hybrid Controls Page Installation Side Mount Cabling...

Page 8: ...d of the control Using the hole in the shift arm furthermost away from the cable mounting support will produce unequal shift travel between the neutral to forward and the neutral to reverse positions...

Page 9: ...n ties The mounted harness should be as far as practical from high current wires or wiring runs and should not be subjected to water fuel lubricants or excess heat Preparation of the Control Head Wiri...

Page 10: ...DELPHI PACKARD CONNECTOR ASSEMBLY METRI PACK SERIES 150 2 DELPHI PACKARD CONNECTOR ASSEMBLY METRI PACK SERIES 150 Yellow Black Red Green Orange Blue TO MV3 E BOAT CONTROL TO ENGINE TAC MODULE D C B G...

Page 11: ...mounting surface with three 3 10 thread cutting screws One screw is 1 50 inches 38 1mm Shift Cable Connection and Adjustment The shift cable must be connected so that the Forward Neutral and Reverse...

Page 12: ...hand lever should be washed lightly with fresh water on a regular basis Periodically check the control head mechanism for loose fasteners and signs of wear on moving parts Keep moving parts well lubri...

Page 13: ...User Manual MV3 E Hybrid Controls Page 13 General Control Dimensions Front View Side View...

Page 14: ...Page 14 User Manual MV3 E Hybrid Controls Mounting Dimensions MV3 E Side Mount Control Note These dimensions are NOT to scale When mounting use the template 311370E which is included with this control...

Page 15: ...ur installation or operation instructions or specifications failed or was damaged due to an accident or abnormal operation including racing misuse or alterations outside our factory was repaired or mo...

Page 16: ...ual MV3 E Hybrid Controls Teleflex Marine 6980 Professional Parkway East Sarasota FL 34240 941 907 1000 FAX 941 907 1020 www teleflexmarine com Teleflex Marine is a division of Teleflex Incorporated 2...

Reviews: