Specifications
The specifications apply when the T3PSX3200 series are powered on
for at least 30 minutes under +20°C – +30°C.
Output Ratings
CH1/CH2
Independent
0 ~ 32V / 0 ~ 3A
0 ~ 32V / 0 ~ 6A(T3PS13206)
CH1/CH2
Series
0 ~ 64V / 0 ~ 3A
CH1/CH2
Parallel
0 ~ 32V / 0 ~ 6A
CH3
5V, 5A(T3PS33203)
0~5V, 1A(T3PS43203)
CH4
0~15V,1A
Voltage Regulation Line
≤
0.01% + 3mV
Load
≤
0.01% + 3mV(rating current
≤
3A)
≤
0.02% + 5mV(rating current > 3A)
Ripple &
Noise
≤
1mVrms (5Hz ~ 1MHz)
Recovery
Time
≤
100µs(50% load change, minimum load
0.5A)
Temperature
Coefficient
≤
300ppm/°C
Current Regulation Line
≤
0.2% + 3mA
Load
≤
0.2% + 3mA
Ripple &
Noise
≤
3mArms
Tracking
Operation
Tracking
Error
≤
0.1% + 10mV of Master (0~32V)(No
Load, with load add load regulation
≤
100mV))
Parallel
Regulation
Line:
≤
0.01% + 3mV
Load:
≤
0.01% + 3mV(rating current
≤
3A)
Load:
≤
0.02% + 5mV(rating current > 3A)
Series
Regulation
Ripple &
Noise
Line:
≤
0.01% + 5mV
Load:
≤
100mV
≤
2mVrms, 5Hz ~1MHz