CP03x/CP03xA Current Probes
4
Specifications
For the most current specifications, see the probe product pages at
teledynelecroy.com. Specifications are subject to change without notice.
Warranted Characteristics
CP030/CP030-3M CP030A
CP031
CP031A
Amplitude Accuracy
±1.0 % of reading to 30 Arms
(45 to 65 Hz)
±2.0% of reading to 50 Apeak
±1.0 % of reading to 30 Arms
(45 to 65 Hz)
±2.0% of reading to 50 Apeak
Bandwidth (probe only) DC to 50 MHz/10 MHz
DC to 100 MHz
Nominal Characteristics
CP030
CP030A
CP031
CP031A
Max Continuous Input
Current at 0.1 V/A
30 Arms
30 Arms
Max Peak Current
50 Apeak non-continuous
50 Apeak non-continuous
Intended Output Load
1 MΩ
1 MΩ
Measured Conductors
Insulated Conductors only
Insulated conductors only
Sensitivity *
10 mA/div to
15 A/div
1 mA/div to
15 A/div
10 mA/div to
15 A/div
1 mA/div to
15 A/div
Offset Range
(1x Attenuation)
N/A
±5 A
N/A
±5 A
Max Continuous Input
Current at 1 V/A
(100mA/div or less)
N/A
5 A
N/A
5 A
* Values are based on oscilloscopes with 1 mV/div sensitivity. Numbers will be higher on instruments with lower
sensitivity.