34
208528 REV M
Operations Manual, 7RU SSPA Chassis
3.1.3 Sys Info Page 3
This page displays miscellaneous information related to the redundancy operation and the
HPA mute status.
•
RFSW1
— Displays the state of RF switch 1, possible values - “Pos1”, “Pos2”,
“N/A”, “FAULT!”;
•
RFSW2
— Displays the state of RF switch 2, possible values - “Pos1”, “Pos2”,
“N/A”, “FAULT!”;
•
State
— HPA online state, possible values “Online”, “Standby”;
•
Mute
— HPA mute state, possible values “Clear”, “Set”;
•
Prior
— Priority polarization select (1:2 Mode Only);
•
PolSel
— Current Polarization output (1:2 Mode Only)
3.1.4 Sys Info Page 4
This page displays various HPA settings:
•
Prtcl
. — Current HPA remote control protocol. Will display “Terminal”, if terminal
mode protocol is currently active and “Normal” if string I/O type protocol is used.
•
Baud
— Selected baud rate for remote control serial port. Selection: “2400”,
“4800”, “9600”, “19200”, “38400”;
•
Intrfc
. — Selected serial port interface. Selection: “RS232”, “RS485”.
•
Addrs
. — HPA remote control network address. Value could be in range from 0
to 254. Note: address 255 is reserved for global calls and should not be used for
an individual unit’s addressing.
•
Buzzer
— Audible alarm availability. “Dis” for disabled or “Enb” for enabled.
•
Latch
— Fault latch option selection. “Dis” for disabled or “Enb” for enabled.
3.1.5 Sys Info Page 5
Page 5 shows settings related to the HPA 1:1 Redundant System operation.
•
Mode
— Indicates HPA operational mode. See
Section 3.3.4
.
•
Stby
. — Shows the HPA standby state selection. “Hot” - Hot standby operation
(HPA retains unmuted state during standby); “Cold” - Cold standby (HPA always
mutes itself in standby mode and unmutes when switched online).
•
Ctrl
. — Shows HPA control style. “Local” - Both local and remote control are
supported; “Remote” - When only remote control provided (keypad locked);
•
Switch
— Indicates switching style. “Auto” - Automatic fault tracking/switching;
“Manual” - If redundancy switching is provided by the operator.
•
Unit
— Redundancy topological factor. “HPA1” - HPA connected to RF switch
port 1 or 4 (Online Position 1 of the RF switch); “HPA2” - HPA connected to RF
switch port 2 or 3 (Online Position 2 of the RF switch).
•
FSpeed
— Displays the current fan speed setting of “Hi”, “Low” or “Auto”.
Summary of Contents for 7 RU Chassis
Page 10: ...10 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Page 30: ...30 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Page 78: ...78 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Page 84: ...84 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Page 94: ...94 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Page 113: ...Operations Manual 7RU SSPA Chassis 208528 REV M 113 Figure 7 8 Terminal Mode Session Example...
Page 138: ...138 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...
Page 144: ...144 208528 REV M Operations Manual 7RU SSPA Chassis THIS PAGE LEFT INTENTIONALLY BLANK...