17-2000 C
2020-09-17
42(50)
ADQ8-8C Manual
17-2000 C 2020-09-17
42(50)
7.6 User scheduled data transfer mode
In the user-scheduled mode the data flow is controlled by the user in a schedule. The user first sets up
the digitizer, then starts the acquisition, and after that requests the data. This is the straight forward
method if the total amount of data is less than the data buffer size (
), that is, it can be stored
in the buffer of the digitizer.
Note that if using readout while recording, the multi-record is not automatically limited by the data buffer
size.
A block diagram of triggered streaming acquisition and user-scheduled data transfer is given in
Figure 32: Re-arm timing.
)
)
&
)
)
&
*+,-
)
)
&
)
)
&
*.+"
"
)
)
&
)
*+