
929412-00 Rev A
40
Firmware Updates
Free firmware updates are available periodically from the Teledyne LeCroy
website at
teledynelecroy.com/support/softwaredownload.
Registered
users will receive email notification when a new update is released.
CAUTION.
Do not install any XStreamDSO software version prior to
8.6.1.8 on WavePro HD oscilloscopes. Doing so will prevent the
oscillosocpe from running as a non-administrative user. You will need
to run the recovery procedure.
To download and install the update:
1. From the oscilloscope desktop (File > Exit) or a remote PC, launch the
browser and visit the software download page at the URL above.
2. Click the link to
Oscilloscope Downloads > Firmware Upgrades
.
3. Enter the required model information and account login. If you don’t
yet have an account, create one now.
4. Follow the instructions to save the installer to a location on the
oscilloscope D: drive or a USB storage device.
5. On the oscilloscope, use Windows Explorer to browse to the installer
file (
xstreamdsoinstaller_x.x.x.x.exe
) and double-click it to launch the
XStream Setup wizard.
6. If prompted, enter the password
SCOPEADMIN
, all uppercase.
7. Follow the wizard prompts.
8. When installation is complete, power cycle the instrument.
CAUTION.
The installation may take several minutes, depending on
the length of time since your last update. Do not power down the
oscilloscope at any point during the installation process.
Switching Users
The oscilloscope is by default set to operate from LeCroyUser, but you must
run the oscilloscope from the Administrative User LCRYADMIN in order
to change Windows settings, run certain compliance packages or use LXI
remote control.
Note:
To install software, it is sufficient to supply the Administrative User
password, SCOPEADMIN.
To switch to the Administrative User profile:
1. Exit the oscilloscope application by choosing
File > Exit
.
2. Open the Windows
Start menu
.
3. Hover over the
Teledyne LeCroy logo
and select user
LCRYADMIN
.
4. Enter the administrative password
SCOPEADMIN
(all uppercase).
5. Double-click the
StartDSO icon
on the oscilloscope desktop.
To return to the default non-administrator account, repeat this procedure
selecting
LeCroyUser
and entering the password
lecroyservice
(all
lowercase).
You may create as many other users on the oscilloscope as you wish,
provided you are logged in to the system as the Administrative User,
LCRYADMIN, when doing so. Use the standard Windows tools to do this.
To ensure the oscilloscope boots into MAUI when running as these other
users, run the command
NetPlWiz
from the Administrative User account.
MAINTENANCE