From the Front Panel 

Turn on/activate

 

digital traces.

Digital

On Mixed Signal instruments, Digital selections are added to the Vertical menu, and the front panel Vertical knobs control active Digital line and bus traces.

Turn 

Offset

 to 

raise/lower group 

Vertical Position

the top of lowest bit 

relative to center.

Turn 

Volts

 to raise/

lower 

Group Height

the total Vertical 

divisions occupied 

by group. 

Digital Descriptor Box 

Digital Memory

# Digital Lines in Group
Digital Sample Rate

Digital Display Modes

Line trace shows high, low and transition points for each line.

Bus trace collapses lines into hex values.

BASICS

Summary of Contents for WavePro HD series

Page 1: ...WavePro HD Oscilloscopes Getting Started Guide...

Page 2: ...stribute Teledyne LeCroy documentation for internal educational purposes Teledyne LeCroy is a trademark of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of th...

Page 3: ...an be downloaded from the Oscilloscope Manuals page on our website at teledynelecroy com support techlib Introduction Introducing WavePro HD Oscillosocopes 2 Safety 3 Overview Front of Oscilloscope 4...

Page 4: ...Oscilloscope Registration Card 1 Calibration Certificate 1 Declaration of Conformity CE Certificate Introducing WavePro HD With up to 5 Gpts of acquisition memory WavePro HD 12 bit oscilloscopes captu...

Page 5: ...input that exceeds the maximum rating of that input Refer to the markings next to the BNC terminals for maximum allowed values Use only within operational environment listed Do not use in wet or explo...

Page 6: ...reen Display B Front Panel C Power On Off Button D Calibration and Ground Terminals E USB 3 1 Ports 3 F Channel Inputs G Ext In H Aux Out I Mixed Signal Interface J Tilting Feet Front of Oscilloscope...

Page 7: ...quire a precision adapter available from Teledyne LeCroy Service to accept SMA cables The tilting feet change the angle of display for easier viewing Powering On Off Connect the line cord rated for yo...

Page 8: ...ower Inlet D Kensington Lock E Ref In and Ref Out Connectors F USBTMC port for remote control and data transfer Back and Side of Oscilloscope G Speaker Out and Mic In H Ethernet Ports 2 OVERVIEW A E D...

Page 9: ...Go to Utilities Utilities Setup Remote to find the IP address To configure a Static IP address touch Net Connections on the Remote dialog and enter the IP address Go to Utilities Preference Setup Emai...

Page 10: ...es two digital banks with separate threshold and hysteresis controls making it possible to simultaneously view data from different logic families Each flying lead has a signal and a ground connection...

Page 11: ...setup files save setups or waveforms to internal memory print the screen to a file or to hardcopy find optimal Vertical Scale for a selected channel etc See the Operator s Manual for instructions When...

Page 12: ...also work as buttons to access other functions If you have a mouse installed you can click anywhere you can touch to activate a control in fact you can alternate between clicking and touching whicheve...

Page 13: ...l as more are opened The Add New box sits next to the trace descriptor boxes Use it to turn on new traces or the Measure table See MAUI with OneTouch on p 15 Timebase and Trigger descriptor boxes appe...

Page 14: ...fault the oscilloscope has the Auto grid mode enabled Auto adds a grid for each new trace up to 20 grids until no more grids are available Other grid modes create a fixed number and orientation of gri...

Page 15: ...d rotated on three axes Line Intensity and Persistence The trace style can be set to a series of separate sample Points or a continuous vector Line Grid Intensity makes the graticule dimmer or brighte...

Page 16: ...scriptor Boxes Channel C1 C4 Zoom Z1 Z12 Math F1 F12 Memory M1 M12 and Digital Digital1 Digital4 descriptor boxes appear along the bottom of the grid area when a trace is turned on Descriptor boxes ar...

Page 17: ...hen you re moving over invalid targets you ll see the Null symbol under your finger tip or cursor Turn On To turn on a new channel math memory or zoom trace drag any descriptor box of the same type to...

Page 18: ...desired source onto the target descriptor box You can also drop it on the Source field of the target setup dialog To change the source of a measurement drag and drop the descriptor box of the desired...

Page 19: ...trigger source channel drag and drop the desired channel Cn descriptor box onto the Trigger descriptor box The trigger will revert to the last coupling and slope polarity set on that channel To place...

Page 20: ...y Mn descriptor box Pan To pan a trace activate it to bring it to the forefront then drag the waveform trace right left or up down If it is the source of any other trace that trace will move as well T...

Page 21: ...ntrols and adjust the zoom exactly To zoom in on any trace unpinch two fingers over the trace horizontally To zoom out on any trace pinch two fingers over the trace horizontally To turn off a trace fl...

Page 22: ...ve or negative Offset The front panel Volts knob also controls the Vertical Scale of zoom math and memory traces Channel Descriptor Box Volts div Gain Offset Pre Processing Summary List changes from d...

Page 23: ...twice to reopen the Cn dialog Refine Volts div or Offset Make other Pre processing settings Note Averaging Interpolation and ERes are disabled on 500 Mpts acquisitions Enter Coupling Enter signal Ban...

Page 24: ...l line and bus traces Turn Offset to raise lower group Vertical Position the top of lowest bit relative to center Turn Volts to raise lower Group Height the total Vertical divisions occupied by group...

Page 25: ...enter a custom Threshold and Hysteresis Separate controls allow you to set different values for each lead bank Choose a Display Mode of individual digital lines bus trace or both Optionally choose a...

Page 26: ...ative Delay time which shifts the triger point left or right The front panel Time div knob also controls the Horizontal Scale of zoom math and memory traces allowing you to zoom in to see more detail...

Page 27: ...Time div in reference to Center 50 of display or Lock to Trigger position see pp 28 29 Use 4 standard or 2 interleaved channels for higher sample rate and memory also higher bandwidth in 6 and 8 GHz m...

Page 28: ...significant part of the acquisition This can be easily done using Timebase controls and or Zoom Navigating with Horizontal Delay Stop acquisition then pan swipe or turn the Horizontal Delay knob unti...

Page 29: ...hen create a zoom trace of the area you wish to analyze Apply math and measurements to the zoom rather than the channel trace Math applied to a zoom is calculated on the entire trace up to 500 Mpts Hi...

Page 30: ...remains at the center of the display Other events move in reference to the center as Time div changes With this setting the trigger point could potentially move off the grid as the scale changes Time...

Page 31: ...the same as Centered but the difference will be apparent if you have used Delay to shift the trigger position Same 2 ms div Timebase with Timebase Reference set to Lock to Trigger starts the same as...

Page 32: ...r visible Triggers Triggers tell the oscilloscope when to perform an acquisition The acquisition starts as soon as the trigger is armed and all trigger conditions are met unless postponed by a Holdoff...

Page 33: ...rigger dialog Choose trigger Type Choose trigger Source channel Set trigger Levels or Find Levels based on the input signal mean Set other conditions such as Slope and Coupling vary by trigger type Ic...

Page 34: ...om Source and Horizontal Scale which differs from the Timebase Adjust Horizontal Scale to change zoom magnification Zoom Zoom traces display a magnified portion of another trace Any trace can be zoome...

Page 35: ...ialog touch Action Toolbar Zoom button to create a new zoom of just that source trace Zoom descriptor opens Zoom dialog to make other adjustments Draw a Zoom box over a portion of the source trace Rep...

Page 36: ...detail in the WavePro HD Oscilloscopes Operator s Manual From the Front Panel From the Touch Screen Cursors Cursor Setup opens the Cursor dialog Touch and drag line to reposition cursor Vertical Curso...

Page 37: ...u can also gate measurements to limit them to a specific region of the trace Note Measurements are constrained to the center 500 Mpts on 500 Mpts acquisitions Shading shows the edges of this Analysis...

Page 38: ...matical function e g Sum Product FFT to one or more source traces One important distinction between math functions and measurement parameters is that the result of math is always another waveform wher...

Page 39: ...only until the oscilloscope is rebooted To store memories indefinitely save them to an external file by choosing File Save Waveform The file can then be recalled into internal memories for viewing by...

Page 40: ...The oscilloscope can be added to a LAN via TCP IP or directly connected to a PC via USBTMC to transfer data Files can also be transferred to a USB drive through any of the host USB ports Stored user d...

Page 41: ...pe that it is still warming up Specifications are not guaranteed during the warm up period Dynamic calibrations may occur during operation to maintain specified performance These are managed by the so...

Page 42: ...s complete power cycle the instrument CAUTION The installation may take several minutes depending on the length of time since your last update Do not power down the oscilloscope at any point during th...

Page 43: ...ng to avoid damage in transit 5 Mark the outside of the box with the shipping address Add ATTN RMA code assigned by Teledyne LeCroy FRAGILE 6 If returning a product to a different country Mark the shi...

Page 44: ...cannot be placed Can be used to remove or add effects of fixtures for which only an S parameter model exists SDA III WPHD SDAIII WPHD SDAIII Complete LINQ delivers integrated jitter and timing analys...

Page 45: ...st first examine the product and find that it is defective due to workmanship or materials and not due to misuse neglect accident or abnormal conditions or operation Teledyne LeCroy shall not be respo...

Page 46: ...etic Field 3 Vrms 0 15 MHz 80 MHz EN 61000 4 11 2004 Mains Dips and Interruptions 0 1 cycle 70 25 cycles 0 250 cycles 4 5 1 To ensure compliance with all applicable EMC standards use high quality shie...

Page 47: ...com patents Safety Compliance EC DECLARATION OF CONFORMITY LOW VOLTAGE The oscilloscope meets intent of EC Directive 2014 35 EU for Product Safety Compliance was demonstrated to the following specific...

Page 48: ...2018 Teledyne LeCroy Inc All rights reserved 929412 00 Rev A May 2018...

Reviews: