HDO4000A Getting Started Guide

43

REFERENCE

Warranty

NOTE:

 THE WARRANTY BELOW REPLACES ALL OTHER WARRANTIES, EXPRESSED 

OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF 
MERCHANTABILITY, FITNESS, OR ADEQUACY FOR ANY PARTICULAR PURPOSE OR 
USE. TELEDYNE LECROY SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, 
OR CONSEQUENTIAL DAMAGES, WHETHER IN CONTRACT OR OTHERWISE. THE 
CUSTOMER IS RESPONSIBLE FOR THE TRANSPORTATION AND INSURANCE 
CHARGES FOR THE RETURN OF PRODUCTS TO THE SERVICE FACILITY. 
TELEDYNE LECROY WILL RETURN ALL PRODUCTS UNDER WARRANTY WITH 
TRANSPORT PREPAID.

The product is warranted for normal use and operation, within 

specifications, for a period of three years from shipment. Teledyne LeCroy 

will either repair or, at our option, replace any product returned to one of 

our authorized service centers within this period. However, in order to do 

this we must first examine the product and find that it is defective due to 

workmanship or materials and not due to misuse, neglect, accident, or 

abnormal conditions or operation. 
Teledyne LeCroy shall not be responsible for any defect, damage, 

or failure caused by any of the following: a) attempted repairs or 

installations by personnel other than Teledyne LeCroy representatives; b) 

improper connection to incompatible equipment; or c) for any damage 

or malfunction caused by the use of non-Teledyne LeCroy supplies. 

Furthermore, Teledyne LeCroy shall not be obligated to service a product 

that has been modified or integrated where the modification or integration 

increases the task duration or difficulty of servicing the instrument. Spare 

and replacement parts, and repairs, all have a 90-day warranty.
The instrument's firmware has been thoroughly tested and is presumed 

to be functional. Nevertheless, it is supplied without warranty of any kind 

covering detailed performance. Products not made by Teledyne LeCroy 

are covered solely by the original manufacturer's warranty.

Windows License Agreement

The XStreamDSO oscilloscope application runs on the Microsoft Windows 

operating system. Teledyne LeCroy’s agreement with Microsoft prohibits 

users from installing third-party software on HDO4000A oscilloscopes that 

is not relevant to measuring, analyzing or documenting waveforms.

Summary of Contents for HDO4000A

Page 1: ...HDO4000A Oscilloscopes Getting Started Guide...

Page 2: ...ibute Teledyne LeCroy documentation for internal educational purposes Teledyne LeCroy is a trademark of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of their...

Page 3: ...nuals page on our website at teledynelecroy com support techlib Introduction Introducing HDO4000A Oscillosocopes 2 Safety 2 Overview Front of Oscilloscope 4 Powering On Off 5 Back and Side of Oscillos...

Page 4: ...d 16 times more resolution than other oscilloscopes Waveforms are cleaner and crisper Signal details often lost in the noise are clearly visible and easy to distinguish and measurements can be perform...

Page 5: ...earest object Keep the underside clear of papers and other objects Exercise care when lifting and carrying Unplug and use the built in carrying handle to move the instrument Do not remove the covers o...

Page 6: ...B Front Panel C Built in Stylus Holder D Power On Standby Button E Input Channels 1 4 F EXT Input G Mixed Signal Interface H Ground and Cal Out Terminals I USB Ports J Rotating Tilting Feet Front of O...

Page 7: ...connecting peripherals such as a mouse or keyboard The rotating tilting feet enable four different viewing positions Powering On Off Plug the line cord only into a grounded AC power outlet See Power...

Page 8: ...yPort Ports B USB 3 1 Gen 1 Ports 4 A B C D E Side and Back of Oscilloscope C Ethernet Ports 2 D Audio Mic and Speaker G REF In Out H USBTMC Port for remote control I AC Power Inlet E Built in Carryin...

Page 9: ...ections from the Remote dialog and use the Windows networking dialogs to configure the device address Go to File File Sharing to configure email Remote Control You can control the instrument over a LA...

Page 10: ...res two digital banks with separate threshold controls making it possible to simultaneously view data from different logic families Each flying lead has a signal and a ground connection A variety of g...

Page 11: ...math and measurement counters F The Adjust knob changes the value in the highlighted data entry field when turned Pushing the Adjust knob toggles between coarse stepped or fine adjustments when the kn...

Page 12: ...Setup Dialogs Touch Screen Display The entire display is active Use your finger or a stylus to touch drag and drop swipe pinch and flick Many controls that display information also work as buttons to...

Page 13: ...ox sits next to the trace descriptor boxes Use it to turn on new traces or the Measure table See MAUI with OneTouch on p 15 The HD Descriptor box shows the ADC resolution at which the oscilloscope is...

Page 14: ...uto Grid Mode enabled Auto adds a grid for each new trace up to 16 grids until no more grids are available Other grid modes create a fixed number and orientation of grids the icon shows the result To...

Page 15: ...es the grid lines dimmer or brighter relative to the trace When more data is available than can actually be displayed Trace Intensity helps to visualize significant events by applying an algorithm tha...

Page 16: ...Traces Trace Descriptor Boxes Channel C1 C4 Zoom Z1 Z8 Math F1 F8 Memory M1 M4 and Digital Digital1 Digital4 descriptor boxes appear along the bottom of the grid when a trace is turned on Descriptor...

Page 17: ...d with a white box When you re moving over invalid targets you ll see the Null symbol under your finger tip or cursor Turn On To turn on a new channel math memory or zoom trace drag any descriptor box...

Page 18: ...e of a trace drag and drop the descriptor box of the desired source onto the target descriptor box You can also drop it on the Source field of the target setup dialog To change the source of a measure...

Page 19: ...hange the trigger source channel drag and drop the desired channel Cn descriptor box onto the Trigger descriptor box The trigger will revert to the last trigger set on that channel To place horizontal...

Page 20: ...escriptor box onto the target memory Mn descriptor box Pan To pan a trace activate it to bring it to the forefront then drag the waveform trace right left or up down If it is the source of any other t...

Page 21: ...the trace you want to zoom Touch the Zn descriptor box to open the zoom factor controls and adjust the zoom exactly To zoom in on any trace unpinch two fingers over the trace horizontally To zoom out...

Page 22: ...fset The front panel Volts knob also controls the Vertical Scale of zoom math and memory traces Channel Descriptor Box From the Front Panel Turn on activate channel trace and open set up dialog Raise...

Page 23: ...dd New box and choose Channel Touch new Cn descriptor to open the Cn setup dialog Enter Attenuation for passive and other vendors probes Enter Volts div and Offset Rescale channel trace or change Vert...

Page 24: ...Displays Line trace shows high low and transition points for each line Bus trace collapses lines into hex values Turn on activate digital traces Turn Offset to raise lower group Vertical Position the...

Page 25: ...open Digitaln setup dialog From the Touch Screen Choose Display Mode of individual lines bus trace or both Line Activity indicators show the state of each line high low or transitioning Optionally cho...

Page 26: ...unless you add positive or negative Delay time The front panel Time knob also controls the Horizontal Scale of zoom math and memory traces allowing you to zoom in to see more detail or zoom out to se...

Page 27: ...vailable From the Touch Screen Touch the Timebase descriptor to open Timebase setup dialog Optionally enter Delay negative time before trigger or positive time after trigger event to show Select Sampl...

Page 28: ...pe when to perform an acquisition The acquisition starts as soon as the trigger is armed and all trigger conditions are met unless postponed by a Holdoff count of time or number of trigger events Trig...

Page 29: ...ch Trigger descriptor to open Trigger setup dialog Choose trigger Type Choose trigger Source channel Set trigger Level or Find Level based on the input signal Icon summarizes the trigger selections Se...

Page 30: ...ore visible BASICS From the Front Panel Create Zoom of all open traces Adjust Horizontal Scale to change zoom magnification Zoom traces Zn display a magnified portion of another trace Any trace can be...

Page 31: ...Zoom box over a portion of the source trace Repeat on another section to reposition the Zoom trace On the source trace setup dialog touch Action Toolbar Zoom button to create a new zoom of just that...

Page 32: ...e waveform and the delta of the two lines From the Front Panel From the Touch Screen Cursors Cursor Setup opens the Cursor dialog Touch and drag cursor line to reposition cursor Vertical Cursor readou...

Page 33: ...eadout in a table below the grid Statistics can be added to the readout along with histicons a miniature histogram of the statistical distribution You can also gate measurements to limit them to a spe...

Page 34: ...s a new trace that displays the result of applying a mathematical function e g Sum Product FFT to one or more source traces Operations can be chained by using one math function as a source for the oth...

Page 35: ...oose Math Memory Setup On the Mn tab select the trace you want stored in Copy From Waveform then touch Copy Now Optionally add Notes or Labels to the stored memory Then drag the descriptor box of the...

Page 36: ...lex user defined patterns and events in the data stream BASICS Select Source trace and Protocol View decoding on the colored overlays When there is more data than fits in a table cell touch the white...

Page 37: ...n modes similar to trigger setups enable a quick search for events of interest The results are time stamped tabulated and can be selected for individual viewing Color overlays mark events on the sourc...

Page 38: ...ou set the inputs and desired frequency span and the oscilloscope automatically generates output in units relevant to the frequency domain A spectrogram generator displays 2D or 3D renderings of histo...

Page 39: ...time stamped with either the absolute time since the beginning of history or the time relative to where you are in the history Not only can individual acquisitions be restored to the grid you can repl...

Page 40: ...oscope is networked LabNotebooks reports and other user data files can be emailed directly from the instrument or saved to accessible network devices Files can also be transferred to a USB drive throu...

Page 41: ...Decode Options provide added insight when debugging serial data For the latest list visit teledynelecroy com serialdata See the product page on our website for a full list of options Online Documentat...

Page 42: ...ge the HDO4000A will meet all specifications Warm up the HDO4000A for at least 20 minutes prior to use During the warm up period the oscilloscope will automatically initiate calibrations to ensure tha...

Page 43: ...st update Do not power down the oscilloscope at any point during the installation process Switching Windows Users Windows 10 oscilloscopes only Windows 10 oscilloscopes are by default set to operate f...

Page 44: ...transit 5 Mark the outside of the box with the shipping address Add ATTN RMA code assigned by Teledyne LeCroy FRAGILE 6 If returning a product to a different country Mark the shipment Return of US man...

Page 45: ...onditions or operation Teledyne LeCroy shall not be responsible for any defect damage or failure caused by any of the following a attempted repairs or installations by personnel other than Teledyne Le...

Page 46: ...etic Field 3 Vrms 0 15 MHz 80 MHz EN 61000 4 11 2004 Mains Dips and Interruptions 0 1 cycle 70 25 cycles 0 250 cycles 4 5 1 To ensure compliance with all applicable EMC standards use high quality shie...

Page 47: ...atents Safety Compliance EC DECLARATION OF CONFORMITY LOW VOLTAGE The oscilloscope meets intent of EC Directive 2014 35 EU for Product Safety Compliance was demonstrated to the following specification...

Page 48: ...2019 Teledyne LeCroy Inc All rights reserved 929955 00 Rev A January 2019...