![Teledyne e2V EV71YC1CNT2010-BA0 User Manual Download Page 28](http://html1.mh-extra.com/html/teledyne-e2v/ev71yc1cnt2010-ba0/ev71yc1cnt2010-ba0_user-manual_1080900028.webp)
UM_NBASE-T_C
OLOUR
REV.E
09/2018
P
A G E
|
28
0 : Off (The Trigger Mask is disabled)
4 : FLO (Exposure Active in the Sensor)
5 : Counter 1 End
6 : Counter 2 End
7 : Timer 1 End
8 : Timer 2 End
9 : L3
10 : L4
11 : L5
12: L6
13 : Frame Valid
14 : Acquisition Active
0x4E060610
TriggerMode_ExposureActive
4
RW
Validation of the Exposure Active Trigger (disabled if
the Line Start Trigger is enabled):
0: Off
1 : On
0x4E060618
TriggerSource_ExposureActive
4
RW
Source for the Exposure Active Trigger :
1 : Line Trigger 1
2 : Line Trigger 2
5 : Counter 1 End
6 : Counter 2 End
7 : Timer 1 End
8 : Timer 2 End
16 : Rotary Encoder Output
0x4E060614
TriggerActivation_ExposureActive
4
RW
Activation of Exposure Active Trigger :
3 : Level High
4 : Level Low
0x4E060628
TriggerMaskActivation_ExposureActive
4
RW
Activation of Trigger Mask for Exposure Active Trigger :
3 : Level High
4 : Level Low
0x4E060624
TriggerMaskSource_ExposureActive
4
RW
Source for the Trigger Mask for Exposure Active Trigger :
0 : Off (The Trigger Mask is disabled)
4 : FLO (Exposure Active in the Sensor)
5 : Counter 1 End
6 : Counter 2 End
7 : Timer 1 End
8 : Timer 2 End
9 : L3
10 : L4
11 : L5
12: L6
13 : Frame Valid
14 : Acquisition Active
0x4E0584A0
TriggerMode_FrameStart
4
RW
Validation of the Frame Start Trigger (disabled if the
Frame Trigger Active is enabled)
0: Off
1 : On
0x4E058344
TriggerSource_FrameStart
4
RW
Source for the Frame Start Trigger :
3 : Frame Trigger
5 : Counter 1 End
6 : Counter 2 End
7 : Timer 1 End
8 : Timer 2 End
15 : Software
0x4E058354
TriggerActivation_FrameStart
4
RW
Activation of the Frame Start Trigger on the Edge :
0 : Rising Edge
1 : Falling Edge
0x4E060640
TriggerMaskActivation_FrameStart
4
RW
Activation of Trigger Mask for Frame Start Trigger :
3 : Level High
4 : Level Low
0x4E060638
TriggerMaskSource_FrameStart
4
RW
Source for the Trigger Mask for Frame Start Trigger :
0 : Off
4 : FLO (Exposure Active in the Sensor)