![Teledyne e2V EV71YC1CNT2010-BA0 User Manual Download Page 19](http://html1.mh-extra.com/html/teledyne-e2v/ev71yc1cnt2010-ba0/ev71yc1cnt2010-ba0_user-manual_1080900019.webp)
UM_NBASE-T_C
OLOUR
REV.E
09/2018
P
A G E
|
19
7
Camera Commands
7.1
Device Control
GenCP address
GenICam Register
Size
(Bytes)
R/W Description
0x00011030
DeviceScanType
4
RO
AreaScan (0) or LineScan (1)
0x0048
DeviceVendorName
32
RO
e2v
0x0068
DeviceModelName
32
RO
NBASE_T_COLOUR
0x00A8
DeviceManufacturerInfo
48
RO
Camera Part Number : EV71C1CNT
xxxx
-BA0
0x0088
DeviceVersion
32
RO
Camera Firmware Version
0x00D8
DeviceSerialNumber
16
RO
Camera Serial Number : YYWW
A
xxxx
0x00E8
DeviceUserID
16
RW
Camera ID set by the User
0x11088
DeviceSFNCVersionMajor
4
RO
2
0x1108C
DeviceSFNCVersionMinor
4
RO
0
0x11090
DeviceSFNCVersionSubMinor
4
RO
0
-
DeviceTLVersionMajor
4
RO
2
(mapped on GevVersionMajor)
-
DeviceTLVersionMinor
4
RO
0
(mapped on GevVersionMinor)
-
DeviceLinkSelector
4
RO
1
DeviceLinkSpeed
4
RO
625000000
-
DeviceLinkHeartbeatTimeout
4
RW
(5s by default)
DeviceLinkCommandTimeout
4
RW
(1s by default)
0x0904
DeviceStreamChannelCount
4
RO
1
DeviceStreamChannelType
4
RO
Transmitter (0),
Receiver (1)
DeviceStreamChannelEndianness
4
RW
Big (0),
Little (1)
DeviceStreamChannelPacketSize
4
RW
-
0x0900
DeviceEventChannelCount
4
RO
1
DeviceCharacterSet
4
RO
ASCII(0),
UFT8(1)
DeviceRegistersEndianness
4
RO
Big(0),
Little(1)
0x4E058098
CameraTemperature
4
RO
Read temperature value of the Device
Format : Q10.2 in degree Celsius (-511/512)
0x4E058078
ElectronicBoardID
32
RO
Production info
0x4E05809C
ElectronicBoardTestStatus
32
RO
Production info
0x4E058114
Reboot
4
WO
Command : Set to 1 to reboot the Camera
-
TimeStampReset
4
WO
Command to Reset the TimeStamp
-
TimestampLatch
4
W0
Command to latch the TimeStamp with Custom Value
-
TimestampLatchValue
32
RW
Value to latch the TimeStamp on Command
0x4E060608
ManufacturerIndex
8
RO
Index of production set in Factory
0x4E058110
Status
4
RO
Camera Status :
Bit0 to 7 :
Reserved
Bit8 : Overflow occurs during FFC calibration
Bit9 : Underflow occurs during FFC calibration
Bit10 : Calibration Error
Bit11 : Scan Direction (Forward : 0, Reverse : 1)
Bit12 :
Reserved
Bit14 : Initialization error
Bit13 :
Reserved
Bit15 : Hardware error detected during init
0x4E060644
MissedTriggerCount
4
RO
Missed Triggers Internal Counter