5. Set the jumpers for the transmit and receive distances, as shown below. (Factory settings are
Low and Short.) See the tables following to determine the settings appropriate for the type of
cable being used.
Figure 4 - Jumper Settings
NOTE:
Transmit and Receive settings are for distance from repeater to network element (or next
repeater) only.
Table 1 - Transmit Settings by Cable Type
Cable
Repeater to NE
distance (feet)
Setting
720
0-124
Low
124-255
High
728
0-212
Low
212-425
High
734
0-224
Low
224-450
High
735
0-112
Low
112-225
High
RG-59
0-224
Low
224-450
High
Jumper Settings
Data Rate
T3 (DS3)
(Default)
1
3
2
4
STS-1
1
3
2
4
E3
1
3
2
4
Transmit
Low
(Default)
1
3
2
High
1
3
2
Receive
Short
(Default)
1
3
2
Long
1