NC/NO output connection
Relay module are designed for both type of relay such NO and NC/NO. Both outputs connection
of NC/NO relay are available on the relay module. To replace NC/NO relay, remove existing NO
relay and insert a new NC/NO relay. Follow the relay module indication for new output wire
connections for NC/NO relay.
COM Configuration
P1~P44 are terminal for COM, changing COM configuration by using wire included inside the
packages. Different size of wire is available.
Symptom
Causes or solution
Transmitter red LED
indicator flashing quickly
(every 0.2 sec) when
operating
One of the pushbuttons is jammed.
Joystick is not in neutral position.
The EMS mushroom is not released completely.
The transmitter is not properly Power-On.
Note
: Please contact the distributor nearest you for further assistant
if need.
Transmitter green/Yellow
LED indicator flashing
crossly when start key switch
on
The joystick #1 memory is damaged. Contact the distributor for
service.
Transmitter red/yellow LED
indicator flashing crossly
when start key switch on
The joystick #2 memory is damaged. Contact the distributor for
service.
Red LED indicator flashing
quickly when start key
switch on
Transmitter main memory is damaged. Contact the distributor
for service.
Transmitter red LED
indicator remains on
permanent
Remove the batteries and re-insert again.
Receiver LED1 indicator
flashing quickly
Receiver main memory is damaged. Contact the distributor for
service.
Receiver does not respond at
all
Switch off main power and switch on again after 20 seconds.
Troubleshooting