CellFax Plus Installation and User Manual
6
3.
Voice/Fax/Data indicator
Voice/Fax/Data LED ON: Call in progress
Voice/Fax/Data LED Flashing: Inbound call in progress
Voice/Fax/Data LED Off: Not in use
4.
S
tart up status indicator
Start up LED ON: Cellfax Plus is initialised successfully
Start up LED Slow Flashing: Cellfax Plus is initialising
Start up LED Quick Flashing Indicates a start-up failure
5.
GSM Signal Status Indicator
GSM signal LEDs ON: identifies Signal Strength
GSM signal Flashing once per second: identifies GSM general errors
GSM signal Flashing 10 times per second: identifies GSM serious error
GSM general errors
(indicated by the signal LEDs)
LED flashing slowly On/Off is defined as “1”
LED Off is defined as “0”
110: No SIM card
010: Network Registration failure
111: GSM/GPRS is in Modem mode
011: PIN code required
GSM serious errors
(indicated by the signal LEDs)
LED flashing Quickly On/Off is defined as “1”
LED Off is defined as “0”
001: Lock Base Station
010: Lock the service provider
011: PIN code error
100: IMSI error
101: Require PUK
110: GSM/GPRS baud rate error
111: other errors