background image

 

 
 

 

 

CellFax

 

Plus

 

 

Installation and User Manual 

 

 

 

Version 1 – May 2009 

Summary of Contents for CellFax Plus

Page 1: ...CellFax Plus Installation and User Manual Version 1 May 2009 ...

Page 2: ...ct voice quality Off power bypass functions when power is off system switches to PSTN network automatically if PSTN connected Modem mode Access the Internet by GPRS through the PC serial port Supports the phone book stored in the SIM card or in the terminal Intelligent routing Able to set up dialing regulation to route voice or fax intelligently Incoming caller display function Auto dialing functi...

Page 3: ...s ICNIRP International Commission on Non Ionizing Radiation Protection and IEEE The Institute of Electrical and Electronic Engineers have developed guidelines to establish the permitted levels of radio wave exposure for the general population Specific Absorption Rate SAR is the unit of measurement for the amount of radio frequency absorbed by the body when using a mobile phone For GSM terminal equ...

Page 4: ...se the battery to moisture water or fire This will make the battery ineffective or unusable 3 Please dispose of the battery in accordance with local rules and regulations Declaration of Conformity Applicant TelecomFM Ltd Address 895 Plymouth Road Slough Berkshire SL1 4LP U K Product CellFax Plus This equipment complies with the European R TTE Directive no 1999 5 EC on radio and telecommunication t...

Page 5: ...ne FAX FAX port connect to regular fax machine PSTN External line port connect to external phone line 2 2 Indicators LEDs Indicators There are 8 indicators on the front panel of the CellFax Plus functioning as follows 1 Power supply indicator Power LED ON DC12V power adapter connected Power LED Off DC12V power adapter disconnected 2 Battery indicator Battery LED ON Battery is in use Battery LED Sl...

Page 6: ...N identifies Signal Strength GSM signal Flashing once per second identifies GSM general errors GSM signal Flashing 10 times per second identifies GSM serious error GSM general errors indicated by the signal LEDs LED flashing slowly On Off is defined as 1 LED Off is defined as 0 110 No SIM card 010 Network Registration failure 111 GSM GPRS is in Modem mode 011 PIN code required GSM serious errors i...

Page 7: ...x Plus back panel 7 optional Connect a landline to the socket marked PSTN on Cellfax Plus back panel Caution Do NOT plug a landline into the Phone socket as this may cause damage 8 Connect the antenna to the socket marked Y on Cellfax Plus back panel 9 Plug one end of the power adapter into the power socket and the other end into the 12VDC power interface indicated on the back panel To turn the Ce...

Page 8: ...m PBX Trunk Connection When connecting to the PBX in this mode you are required to connect to the Phone port on the back of the unit PBX relay mode application 32B Mode 1 3 with no sim PBX Extension Connection When connecting to the PBX in this mode you are required to connect to the PSTN port on the back of the unit PBX extension access mode application ...

Page 9: ... if you receive another call you will hear Du Du tone You now have the following options To ignore the incoming call take no action To reject the incoming call press the R button and then press 0 To end the current call and answer the new call press the R button and then press 1 or hang up the phone to end the current call the phone will start ringing and the new call can be answered by picking up...

Page 10: ...y attaching a regular G3 Analogue fax machine to the Fax port on the back panel of the Cellfax Plus unit The device supports two fax receiving mode synchronous mode and asynchronous mode the mode can be set using a keypad command see section 4 4 2 Note Ensure that the SIM card in the unit has a separate Fax number for receiving faxes 4 3 Data Function User can transmit data by attaching a regular ...

Page 11: ...er Manual 11 4 3 1 Installing the Modem From the Start Menu click Control Panel Note If the screen displayed differs to that shown here click Switch to Classic View Double click Phone and Modem Options Select the Modems Tab Click Add ...

Page 12: ...stallation and User Manual 12 Select Don t detect my modem I will select it from a list Click Next Ensure that Standard Modem Types is selected on the left and click on Standard 19200 bps Modem on the right Click Next ...

Page 13: ...CellFax Plus Installation and User Manual 13 Select the serial port that the CELLFAX PLUS is attached to and click Next Click Finish ...

Page 14: ...CellFax Plus Installation and User Manual 14 Click OK The CELLFAX PLUS is now installed as a modem on your PC If you query the modem then make sure the serial port switch is set 83 2 ...

Page 15: ...nt has already been set up with a service provider You will have been given Telephone number for the dial up connection Username and Password From the Start Menu click Control Panel Double click Network Connections Click Create A New Connection Click Next Select Connect to the network at my workplace and click Next ...

Page 16: ...lus Installation and User Manual 16 Click Dial up connection and click Next Click Next Enter a name for the connection and click Next Enter the phone number for your internet provider and click Next Click Finish ...

Page 17: ...o your Internet provider and log you on 4 3 3 Disconnecting from the Internet When on line there is a computer icon in the bottom right corner of the screen that flashes whenever data is being transferred To terminate the connection right click on this icon and click on Disconnect The CELLFAX PLUS will then go off line and return to voice mode after a few seconds ...

Page 18: ...S the Cellfax Plus requires a GPRS enabled SIM Card and the following information must be provided by the Network Operator Access Point Name APN Username Password Increase port speed and add Advanced Settings Click Start Settings Control Panel Double click Phone and Modem Options Click on the Standard 19200 bps Modem and click Properties Change the Maximum Port Speed setting to 115200 Click on the...

Page 19: ...odem options screen Configure connection Refer to the section 4 3 2 Connecting to the Internet for instructions on setting up an internet connection Right click the connection and choose Properties Click Configure and change the modems Maximum Speed to 115200bps Click OK When prompted for a Username and Password enter the Username and Password provided by the Network Operator When prompted for a p...

Page 20: ... mode 4 Set dial mode Command 333 n Set the terminal dialing mode n 0 is audio dial mode n 1 is pulse dial mode 5 Set auto dialing delay Command 3 seconds Set up dialing time and auto sending out time upon completely entry of numbers default setting 3 seconds seconds Set point range 1 20 sec 6 Set external line flash key delay Command 4 flashDelay Set external line flash key delay default 700ms de...

Page 21: ...onous Default n 0 4 4 3 Call Diverts 1 Set the FXO call diversion type Command 75 n Description Set the FXO call diversion type 0 divert always 1 divert when no answer 2 do not divert 2 Set the divert number from FXO to GSM Command 71 Number Description Set the divert number from FXO to GSM Number is the number which will be dialled from GSM port 3 Set the call divert switch from GSM to FXO Comman...

Page 22: ...Off 1 ETSI DTMF 2 ETSI V 23 3 Bellcore Default value is 3 3 Set keyboard command for transmitting caller ID during calling Command 82 n Description Set keyboard command for whether or not to transmit caller ID during calling 0 No transmit 1 Transmit 4 4 5 Set Serial port Mode 1 Set serial port mode Command 83 n Description Set serial port mode 0 Off 1 CLI 2 MODEM 4 4 6 SIM Card settings 1 Input PI...

Page 23: ...ncy number you are required to remove 112 by entering command 672 0 3 Delete all the emergency call number Command 670 Description deletes all the emergency number that was set 4 Show all the emergency call number require LCD Command 671 Description Show all the emergency number that was set NOTE Emergency Calls This terminal operates using GSM signals which cannot guarantee connection in all cond...

Page 24: ... international call except the homeland 4 GSM all incoming call restriction Command 35 PW BS Description GSM restrict all the incoming call 5 GSM all incoming call restriction roam Command 351 PW BS Description GSM restrict all incoming call during roaming 6 GSM enable disable call waiting Command 43 Description GSM enable disable call waiting function ...

Page 25: ...tenna TNC female 50Ω SIM card 3V SIM card Phone port Impedance 270Ω 750Ω 150nF default Open circuit voltage OCV 50V on hook Feed current 25mA off hook Ringing Load Supports integrating 3 phones Max 3REN Working Environment Operating temperature 0 45 Operating humidity 20 75 Storage temperature 20 60 Storage Humidity 5 95 Dimensions Length Width Height 20cm 15cm 4cm Weight 0 5kg Battery backup if s...

Page 26: ...that For sending faxes ensure the SIM card data transmission service is available GSM network support is required For receiving ensure the SIM card receiving fax service is available GSM network support is required usually this function needs dual numbers one voice number and one fax number For fax receiving use only the fax number Q What type of fax machine do I need to use A CELLFAX PLUS is in l...

Page 27: ...ccept no liability for any error or damages of any kind resulting from the use of this document or the equipment it relates to 3 No responsibility is assumed by TFM for the use or reliability of the Cell Fax Plus when used in a situation or with other equipment not supplied or specified by TFM 4 The wording in this document may change from time to time Please refer to the TelecomFM web site www te...