58
www.behnke-online.de
myintercom Plus IP video door intercom Instructions
Add-on modules
GB
The door station is reset with the help of the
Reset button , if the anti-tamper contact
has tripped. To do this, ensure that the hous-
ing cover of the IP door station is screwed on
and press the button on the security relay
for at least 2 seconds.
A door opener (12 V DC/AC max. 9 W) can be
connected directly to the terminals of the
security relay marked “door opener”. Option-
ally, it can also be operated with an external
power supply at relay 1. Please note that the
door opener voltage and relay 1 are always
switched simultaneously.
Equally, with this add-on module it is also
possible to use a second, additional relay.
This can be used, for example, to control a
garage door opener, a second door opener, a
barrier or the outdoor lighting.