SEECTOR User Manual
seector00.doc 27.04.00
29
8. User set-up
The console enables the operator to customise their working
environment. These settings are found in the user menu. All settings
stored under the user menu are part of the user setup.
8.1 User menu
8.1.1 General
All special options the operator can specify are selected
under the user menu. All settings here are part of the saved
user setups.
Changes in the setups give immediate effect.
The following parameters are defined in the user set-up
menu:
8.1.2 Assign options
This setting is done for every source and destination. Press
the assign switch to select.
The general AUTO ASSIGN switch enables or disables the
complete autoassign function. When the function is
enabled, the following switches can be set to perform
autoassign:ON-switch is activated
•
CUE-switch is activated
•
SOLO-switch is activated
•
FADER switch is activated
8.1.3 Fader options
ON SWITCH ALWAYS ON shall lock all on switches in their
on position. If this is selected the other fader options are
disabled.
ON SWITCH OFF BY CLOSING FADER. Whenever the
fader is closing to its off position, the on switch is also
switched off
ON SWITCH DEFAULT ON sets all ON switches to on at
system power up and user set-up changes.
8.1.4 Monitor options
These options are set independently for each speaker set.
Use the assign button on the monitor panel to select a
speaker set. For other types of panels these options are
disabled.
Refer to the monitor section for description.