SEECTOR User Manual
seector00.doc 27.04.00
16
While the control is turned the destination list is shown in the monitor
assign window and the actual selected destination is shown in the
panel displays.
Selecting a destination changes all settings for the strip including
source selection.
One of the destination options is a blank no-selection. When this is
selected the strip is redefined as an input/source strip.
If the channel is on air, destination select is not permitted and the
availability indicator is off.
Every strip holds its own destination reduction list that can reduce the
amount of destinations possible for the given channel. The
destination reduction lists are defined in the user set-ups, and is
stored as part of the user set-up.
Input controls
•
Gain rotary control
•
Light bar
•
Illuminated Left switch
•
Illuminated Right switch
•
Illuminated 48V switch (Microphone source only)
•
Illuminated coarse gain switch (Microphone source only)
•
Illuminated Phase shift switch
The gain rotary control adjusts the level of the source between given
fixed limits. The light bar indicates the gain setting.
Two switches marked left and right selects which input to be used.
When no switch is selected the source is treated as stereo.
When one switch is selected this input is used for both left and right
output.
When both are selected the channel uses both left and right input in
mono sum.
Coarse gain adjustments are performed with the gain rotary control
when the coarse switch is selected.
The 48V phantom power switch is enabled for microphones only.
The phase switch reverses the phase of the source signal. For stereo
sources only the left input is reversed when active.
Channel controls
•
Illuminated Filter switch
•
Illuminated Equaliser switch
•
Illuminated Insert switch
•
Illuminated Dynamics switch
U