GHN-AT-PROG-UPLC-3-SLOPE Reference Manual
Page 1 of 12
1.0
Personnel Safety Warning
For personnel safety, the metal enclosure of the GHN-AT-PROG-UPLC-3-SLOPE must be earth grounded.
Connect one end of an AWG16 cooper wire to the lug provided with the enclosure and the opposite end of the
wire to the facility earth ground.
2.0
System Requirements
Windows 7, 10
.Net Framework 3.5
USB 2.0 Cable A Male to Mini B Male
3.0
Specifications
Number of Channels
3
Frequency Range
1 to 100 MHz
Attenuation Range
1 to 100 dB (1-dB steps)
Attenuation Accuracy
+/- 0.5 dB
Slope Filter
Monotonically increasing in attenuation from 1 to 100 MHz
Typ. 1 dB ±1dB at 1MHz
10 dB ±1dB at 30MHz
20 dB ±1dB at 100MHz
Port Type
SMA Female Connectors
Impedance
50 Ω
Return loss
≤ -15dB
Power Rating
+20 dBm
Interface
MINI-B USB PORT