SySTEm FuNCTiONS
frequency
System 860 uses 69 different frequencies, which makes it possible to use several transmitters and receivers
within the same coverage area.
Battery status
The transmitter has an integrated battery indicator which shows when only approx. 10% of the battery capacity
remains.
automatic shut-off
The transmitter has an automatic shut-off function built-in to conserve battery power. The available selections
for automatic shut-off are: after 2, 6 or 12 minutes, or no automatic shut-off.
Pin code
Up to 10 individual/personal PIN codes can be programmed on each transmitter.
time delay between pushbuttons
Time delays can be programmed between pushbuttons and between first and second step in the pushbutton.
Logging off/on
The receiver can be programmed to accept up to three different transmitters, where each transmitter has its
own unique code. For reasons of safety only one transmitter at a time can be logged on. The current transmit-
ter must first be logged off before another transmitter can be logged on.
function selection
The system offers the possibility of programming different combinations of relay functions.
momentary or latched relay functions
Each function relay can be programmed for momentary or latched relay operations.
interlocking
Using this function it is possible to interlock/prioritise a relay function/button before another. If interlocking has
been programmed and two buttons on the transmitter are pressed simultaneously, one of the buttons is given
priority/interlocked over the other, which means, for example, up and down movements can not be operated at
the same time.
Safety relay
The receiver is supplied with two safety relays, which are continuously monitored.
integrated safety function when the transmitter starts: 0-position monitoring
If any button is inadvertently pressed when the transmitter is starting, the transmitter will not start. This is