background image

 

 

/+[Y]/[X]:******. 

Send  embedded  RS-232  commands  to  device  at 
HDBaseT receiver. 

  Y is for RS-232 port (connect with RS-232 port of 

HDBaseT receiver) 

Value = 1,2,3,4,5,A,B,C,D,E,F,G or H 

The  value  of 

is  defined  into  the  following 

meanings  (in  a  given  baud  rate  depended  by  the 
value of X): 

a. 

Y = 

1

2

3

 or 

4

, send this command to the 

corresponding HDBaseT receiver to control far-end 
device. 

b. 

Y = 

5

, send this command to all HDBaseT receivers 

to control all far-end devices. 

c. 

Y = 

A

B

C

 or 

D

 

d. 

Y = 

E

F

G

 or 

H

 

For  items 

c

  or

  d

,  send  this  command,  it  will  be 

saved  to  the  matrix  switcher  but  taken  without 
action to corresponding HDBaseT receiver. And its 
command  function  will  be  effective  almost  at  the 
same  time  when  you  send  the  command 

PWON

 

(for item 

c

) or 

PWOFF

 (for item 

d

). 

Note:  

&

 E 

are for port

 1. 

&

 F 

are for port 

2. 

&

 G 

are for port 

3. 

D

 &

 H 

are for port 

4.

 

  X is for bound rate (Value ranges from 1 to 7, 1 is 

for 2400, 2 for 4800, 3 for 9600, 4 for 19200, 5 for 
38400, 6 for 57600 and 7 for 115200) 

 

***** is for data (

Max length 48 Bytes

)

 

The symbol 

“.” is the end of one command. If there 

are some symbols of 

“.” in one command, this case 

is allowed and the last one is the end. 

%0801. 

Enable inputs with HDCP management. 

%0800. 

Disable inputs with HDCP management. 

%0900. 

Set as infrared carrier following mode. 

%0901. 

Set as infrared carrier enforcing mode. 

%0911. 

Reset to factory default. 

%9951. 

Check the command sent by port 1 when PWON. 

%9952. 

Check the command sent by port 2 when PWON. 

%9953. 

Check the command sent by port 3 when PWON. 

%9954. 

Check the command sent by port 4 when PWON. 

%9955. 

Check the command sent by port 1 when PWOFF. 

%9956. 

Check the command sent by port 2 when PWOFF. 

%9957. 

Check the command sent by port 3 when PWOFF. 

%9958. 

Check the command sent by port 4 when PWOFF. 

%9961. 

Check the system locking status. 

%9962. 

Check the status while in standby mode. 

%9963. 

Check the working mode of infrared carrier. 

%9964. 

Check  the  IP  address  (

only  for  the  PCB  with 

GUI

). 

Summary of Contents for TEK-MHD44TP 79055

Page 1: ...TEK MHD44TP 79055 4x4 HDMI Matrix with HDBaseT Lite Outputs TEK TPHD402PR User s Manual March 15 2014...

Page 2: ...ed information Copyright 2014 TEKVOX Inc No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of TEKVOX Inc All rights reser...

Page 3: ...30 F To avoid any damage by over heat please provide adequate ventilation to radiate the heat when operating the device The device should be turned off when in wet or humid areas The AC power supply...

Page 4: ...TEM DIAGRAM 5 6 SYSTEM OPERATION 6 6 1 FRONT PANEL BUTTON CONTROL 6 6 2 IR CONTROL 6 6 2 1 IR Remote Operation 7 6 2 2 IR Operations 8 6 3 RS 232 CONTROL 12 6 3 1 Commands 12 6 3 2 Control the HDBaseT...

Page 5: ......

Page 6: ......

Page 7: ...werful EDID and HDCP management HDBaseT Lite outputs to transmit HDMI IR RS 232 up to 200 feet over a single Cat 5e Cat 6 cable Output PoE provides power for all the receivers connected to the HDBaseT...

Page 8: ...annel No 3 Operation Press buttons in this order 1 AV 3 ALL outputs button To transfer one input to all outputs Example To transfer both AV and IR signals from input channel No 1 to all output channel...

Page 9: ...n IR transmission with the IR OUT on the corresponding HDBaseT receiver HDMI Split HDMI output for local monitoring COAX HDMI de embedded digital audio output HDBaseT Works with receivers using HDBase...

Page 10: ...minimum of 30 feet Cat 5E or Cat 6 solid twisted pair cable TIA EIA T568A TIA EIA T568B Pin Cable color Pin Cable color 1 green white 1 orange white 2 green 2 orange 3 orange white 3 green white 4 blu...

Page 11: ...TEK MHD44TP 4x4 HDBaseT Matrix TEKVOX INC 5 www tekvox com 210 348 6565 5 System Diagram...

Page 12: ...the input is with HDCP Y means the input signal is with HDCP N means not Check if the output is with HDCP Y means the output signal is with HDCP N means not Check the output resolution Use the UP and...

Page 13: ...have the same function as the front panel THROUGH To transfer the signals directly to the corresponding output channels Example Press 3 THROUGH the result will be IN 3 OUT 3 Press ALL THROUGH the resu...

Page 14: ...matrix switcher received by a controlled device See figure below Switching Operation a Sending command x1 R x2 reference to 6 3 RS 232 Control x1 Corresponds to one of the 4 IR OUT ports of the matrix...

Page 15: ...ed with an HDBaseT receiver or IR ALL IN port of the matrix is not with IR carrier you need to send the command 0901 to transfer the IR signal to IR OUT port Control far end output device from local T...

Page 16: ...ar end device through IR ALL IN port The IR signal received from IR ALL IN port will be transmitted to all the four far end HDBaseT receivers connected to HDBaseT ports on the matrix switcher See figu...

Page 17: ...ponding IR OUT port of the HDBaseT 4x4 matrix switcher See figure below Controlled by a Third party IR Control Device Use the included IR converting cable see as below to connect the HDBaseT matrix to...

Page 18: ...ration Operation Command x All Transfer signals from the input channel x to all output channels All Transfer all input signals to the corresponding output channels respectively All Switch off all the...

Page 19: ...r working status Value 1 or 0 Y I Z 1 means the input port is compliant with HDCP Y O Z 1 means output with HDCP Y I Z 0 means the input port is not compliant with HDCP Y O Z 0 means output without HD...

Page 20: ...lue ranges from 1 to 7 1 is for 2400 2 for 4800 3 for 9600 4 for 19200 5 for 38400 6 for 57600 and 7 for 115200 is for data Max length 48 Bytes The symbol is the end of one command If there are some s...

Page 21: ...data via the RS 232 port X is for input port When the value of X is 5 upgrade all 4 input ports When the switcher gets the command it will show a message to send EDID file bin file Operations will be...

Page 22: ...witcher connect its 9 pin female RS 232 port to a PC s or control system s RS 232 port It is also possible to control the Matrix using one of the HDBaseT receiver s RS 232 ports Control the HDBaseT 4x...

Page 23: ...a device at the HDBaseT receiver This method does not allow for bi directional control Please reference to the detailed command description in 6 3 1 RS 232 Commands Control far end device from local...

Page 24: ...nect a computer to the network port you must use a crossover network cable or network switch Set its IP address of the PC to the same IP VLAN as the default IP is address or the unit 192 168 0 178 Ent...

Page 25: ...gs Make certain the new IP address is written down Best to keep the IP address settings listed on the on Matrix You cannot get these settings from the front panel menus After configuration reset devic...

Page 26: ...type the command using a Telnet program 7 Firmware Updating To meet with the request of different users or add function in future the firmware of TEK MHD44TP can be upgraded via USB When you need to...

Page 27: ...DID data and manual EDID management HDCP Supports HDCP 1 3 auto and manual HDCP management Audio General Output Signal Stereo audio Digital audio Output Connector 4 3p captive screw connectors 4 Coax...

Page 28: ...l operating conditions or non TEKVOX authorized modifications to said product If it has been determined product is defective please call TEKVOX and ask for an Applications Engineer at 210 348 6565 USA...

Reviews: