Command
Description
Command & Feedback
Example
#GET_SYNCACT_RS232
Get whether to send the
corresponding RS232 command
when detecting a Power On/Off
signal
@SYNCACT_RS232 1
#SET_DTIME
[PARAM1]:[PARAM2]
Set the delay time for
automatically sending the
Display Off command when no
signal is detected
[PARAM1]
= 0~30 minutes
[PARAM2]
= 0~1800 seconds
#SET_DTIME 1:30
@DTIME 1:30
#GET_DTIME
Det the delay time for
automatically sending the
Display Off command when no
signal is detected
@DTIME 1:30
#SET_AUTO_POWER
[PARAM]
Enable/Disable Auto-Standby
function
[PARAM]
= 0~1
0
–
Disable
1
–
Enable
#SET_AUTO_POWER 1
@AUTO_POWER 1
#GET_AUTO_POWER
Get the Auto-Standby status
@AUTO_POWER 1
#SET_OFF_CNT [PARAM]
Set the number of times to send
the Display Off command
[PARAM]
= 1~2
#SET_OFF_CNT 1
@ODD_CNT 1
#GET_OFF_CNT
Get the number of times to send
the Display Off command
@OFF_CNT 1
#SET_OFF_DELAY [PARAM]
Set the interval between
sendings of the Display Off
command
[PARAM]
= 5~100 (1 = 100 ms)
#SET_OFF_DELAY 5
@OFF_DELAY 5
#GET_OFF_DELAY
Get the interval between
sendings of the Display Off
command
@OFF_DELAY 5