Figure 4–7: VM700A Luminance “Non Linearity” Measurement Screen
6. Check Luminance Amplitude Accuracy
a. Select the NTC7 Composite signal from the TSG 95 (press K).
b. Press the following VM700A keys: Measure, <Bar LineTime>, and
Average.
c.
CHECK — that Bar Level is 714.3 mV
±
7.143 mV (100 IRE
±
1 IRE).
See Figure 4–8.
NOTE
. The Bar Amplitude measurement on the VM700A is equivalent to the
Luminance Amplitude specification called out in the Specifications section of
this manual.
Summary of Contents for TSG 95
Page 4: ......
Page 6: ...TSG 95 Service Manual...
Page 14: ...Service Safety Summary viii TSG 95 Service Manual...
Page 30: ...Specifications 1 16 TSG 95 Service Manual Figure 1 5 PAL Green Field Figure 1 6 PAL Blue Field...
Page 35: ...Specifications TSG 95 Service Manual 1 21 Figure 1 15 PAL Reduced Sweep Figure 1 16 PAL Pluge...
Page 40: ...Specifications 1 26 TSG 95 Service Manual Figure 1 25 PAL Matrix Signal UK ITS 2...
Page 41: ...Specifications TSG 95 Service Manual 1 27 Figure 1 26 PAL Safe Area...
Page 43: ...Specifications TSG 95 Service Manual 1 29 Figure 1 28 SMPTE NTSC Color Bars Zero Setup...
Page 50: ...Specifications 1 36 TSG 95 Service Manual Figure 1 41 NTSC Convergence Components...
Page 53: ...Specifications TSG 95 Service Manual 1 39 Figure 1 46 NTSC Cable Sweep Figure 1 47 NTSC Matrix...
Page 54: ...Specifications 1 40 TSG 95 Service Manual Figure 1 48 NTSC Safe Area...
Page 104: ...Performance Verification and Adjustment Procedures 4 30 TSG 95 Service Manual...
Page 118: ...Maintenance 5 14 TSG 95 Service Manual...
Page 134: ...TSG 95 Service Manual 7 8...
Page 139: ...Replaceable Mechanical Parts 8 5 TSG 95 Service Manual A1 A2 A3 Figure 1 Exploded View...
Page 140: ...Replaceable Mechanical Parts 8 6 TSG 95 Service Manual...