Clear and Sanitize Procedures

The following terms are used in the tables in this section:

Type of user info stored

This column describes the type of user information that is stored in the device.

User data.

Waveforms and other measurement data that represent signals that users connect to the instrument.

User settings.

Instrument settings that the user can change.

Both.

Both user data and user settings are stored in the device.

None.

Neither user data nor user settings are stored in the device.

Method of modi

fi

cation

This column indicates the method of modifying data:

Direct.

The user can modify the data.

Indirect.

The instrument system resources modify the data. The user cannot modify the data.

User accessible

This column indicates whether the user can retrieve the device contents:

Yes.

The user can directly retrieve the memory device contents.

No.

The user cannot retrieve the memory device contents.

To clear

This column tells how to clear data from the media or memory device before reusing it in a secured area. All reusable
memory is cleared to deny access to previously stored information by standard means of access.

To sanitize

This column tells how to eradicate the data from the media or memory device so that the data cannot be recovered by
other means or technology. This is typically used when the device will be moved (temporarily or permanently) from a
secured area to a nonsecured area.

TDS1000B/TDS2000B, TDS1000C-EDU/TDS2000C, and TPS2000B Series

1

Summary of Contents for TDS1001B

Page 1: ...TDS1000B TDS2000B TDS1000C EDU TDS2000C and TPS2000B Series Digital Storage Oscilloscope ZZZ Declassification and Security Instructions xx www tektronix com 077 0445 00...

Page 2: ...and pending Information in this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tek...

Page 3: ...Preface iii Clear and Sanitize Procedures 1 Memory Devices 2 Data Export Devices 5 Troubleshooting 7 How to Clear or Sanitize a Nonfunctional Instrument 7 TDS1000B TDS2000B TDS1000C EDU TDS2000C and...

Page 4: ...Table of Contents ii TDS1000B TDS2000B TDS1000C EDU TDS2000C and TPS2000B Series...

Page 5: ...rument If you have any questions contact the Tektronix Technical Support Center at www tektronix com support Reference The procedures in this document are written to meet the requirements specified in...

Page 6: ...nual name Tektronix part number TDS1000B and TDS2000B Series Digital Storage Oscilloscope Service Manual 071 1828 XX TDS2000C and TDS1000C EDU Series Digital Storage Oscilloscope Service Manual 077 04...

Page 7: ...ll supplied to the instrument For the purpose of clearing data putting the instrument in Standby mode does not qualify as powering off For these products you will need to either push a rear panel OFF...

Page 8: ...Preface vi TDS1000B TDS2000B TDS1000C EDU TDS2000C and TPS2000B Series...

Page 9: ...stem resources modify the data The user cannot modify the data User accessible This column indicates whether the user can retrieve the device contents Yes The user can directly retrieve the memory dev...

Page 10: ...gs No Indirect Firmware operations Main Acquisition board TDS models only No Remove power from the instrument for at least 20 seconds Remove power from the instrument for at least 20 seconds Real time...

Page 11: ...in user data or settings Cleaning would disable instrument functionality Not applicable does not contain user data or settings Sanitizing would disable instrument functionality Clear Flash Procedure T...

Page 12: ...e front of the oscilloscope For TPS oscilloscopes insert a compact flash card into the Compact Flash slot on the front of the oscilloscope 14 Push the front panel UTILITY button 15 Push the Options op...

Page 13: ...strument setups Directly Save Front panel Files can be deleted or overwritten on the oscilloscope or a PC USB flash drive can be removed and destroyed The USB host port cannot be disabled USB device p...

Page 14: ...Clear and Sanitize Procedures 6 TDS1000B TDS2000B TDS1000C EDU TDS2000C and TPS2000B Series...

Page 15: ...regarding handling or disposal of the board Compact Flash Card TPS oscilloscopes only Remove the compact flash card and return the instrument to Tektronix for repair After removal of the compact flas...

Reviews:

Related manuals for TDS1001B