Iris Packet Broker (IPB) 7.13.2
11
Hardware Installation and Maintenance Guide
2
IPB Hardware Reference
Rev. 001-140228
IPB220 and IPB420 Rear Panel
The rear panel for the IPB220 and the IPB420 have the same components (
).
Figure 2.2 - IPB220 and IPB420 Rear Panel (AC Unit Shown)
describes the IPB Rear Panel components.
Grounding Lugs
Alarm Relay (not used)
Management
Ports (2)
Fan Tray
Power Supply 1
Power Supply 2
Console
Port
PPS SMA
Connector
GPS/1PPS
Port
PTP
Port
Table 2.3 - IPB Rear Panel Component Descriptions
Item
Description
Alarm Relay
Not used.
Grounding Lugs
Tektronix provides a two-hole grounding lug kit with the AC or DC cabling kit.
The grounding lug must be installed on the IPBs to ensure proper electrical
protection.
Management Ports
RJ45 connectors supporting 10/100/1000 Gigabit Ethernet. Port 1 provides
network connectivity to LAN for communications to Iris Server.
GPS/1PPS Port
RS-422 connection used for time synchronization with GPS source. GPS
synchronization is based on receipt of a 1PPS signal and the TSIP protocol (for
time of day and other data).
Measure the length of the cable from the IPB to the GPS receiver; you will need
to know this length when configuring GPS timing source in the IPB GUI to
achieve the expected accuracy. Refer to the IPB System Software Guide for
details about time stamping synchronization.
PTP Port
Used for time synchronization using a Precision Time Protocol (PTP) source.
PTP synchronization requires communication with a PTP Master Clock server
over an Ethernet or IP network, where the IPB will be a PTP Slave.
1PPS SMA Connector
PPS SMA connector used for time synchronization with Pulse Per Second
(PPS) source.