Characteristics
—Type
535A
Accessories
Standard
Accessories supplied with the Type 535A are
listed
on the last pullout
page of the Mechanical Parts List
Illustrations.
For optional
accessories available for use with
this instrument,
see the current Tektronix, Inc. catalog.
standardization of the main-unit vertical amplifier
transient
response
of
a
Tektronix convertible oscilloscope. Risetime
of
the
Type P is approximately 4
nanoseconds when it
is
used
to
standardize a
Type 540-Series Oscilloscope.
Pulse
repetition
rate is
240 step functions per second, with either
positive or
negative polarity. Step function amplitude is
continuously
adjustable between 0 and 3 major graticule
divisions.
Type
N
Type
Q
The
Type N Sampling Unit
is designed
for use with Tek
tronix
plug-in
type Oscilloscopes. The sampling
system thus
formed
permits
the display of repetitive signals with frac
tional
nanosecond (10-9 second
or nsec) risetime. By taking
successive
samples at a
slightly later time at each recur
rence
of the pulse under observation, the Type N
recon
structs
the pulse on a relatively long time-base. Specifica
tions
of the Type N include a risetime of 0.6 nsec, corresond-
ing
to a maximum bandpass of approximately 600 mc; a
sensitivity of
10mv/cm
with 2 mv or less noise; and a
dynamic
range of ±120 mv minimum linear range before
overloading results.
The Type Q
Plug-In Unit permits
any Tektronix convert
ible
oscilloscope such as the Type 535A to
be operated
with
strain
gages and other
transducers. Excitation voltages
for the
strain gages and transducers are provided by the
plug-in
unit. The unit provides
high gain, low noise, and
extremely
low
drift. Frequency response of the Type Q
Plug-In
Unit
is
DC
to
6 kc; risetime is approximately 60
microsecond.
Strain sensitivity is calibrated in 10 steps
from
10 microstrain per major graticule division to 10,000
microstrain
per division, and
is
continuously variable
be
tween
steps.
Accidental overload of
±4 volts de is permissible.
Fig.
1-2. Type
535A Oscilloscope Dimensions.
Type
P
The Type
P Plug-In Unit
generates a fast-rise step-function
test signal
of
known waveform, simulating the output of
an
ideally
compensated
Type K Unit driven with a Tektronix
Type
107 Square-Wave Generator. The Type P
permits the
Type
R
The Type
R Plug-In Unit
is a combined power supply and
pulse generator which
is used to measure
the high-frequency
characteritics
of junction transistors by the pulse-response
method.
When the
Type R is used in an oscilloscope hav
ing
a
delay
line; delay time, risetime, storage time, and
falltime
may
be
displayed simultaneously. A
push-button
switch
connects
a front-panel terminal directly to the input
of
the oscilloscope for
observing externally derived wave
forms.
Pulse risetime
of the
Type R unit is less than 5 nanosec
onds, so measurements depend
on
the risetime of the oscil
loscope
used. Pulse amplitudes are in 8 fixed, calibrated
steps from .05 to 10 volts,
adjustable between steps. Pulse
recurrence
frequency
is 120
pulses per second.
Type
S
The Type
S Plug-In Unit is designed for use with Tektronix
Wide-Band
convertible oscilloscopes.
The slower risetime
of
the Tektronix 530-Series Oscilloscopes will affect the
ability
of
the S Unit
to analyze fast semiconductor diodes.
Using
the Type
S, voltage across a test diode is displayed
as a
function of time.
Certain diode
parameters, such as
junction resistance,
junction
capacitance, and the stored charge at the junction,
can
be measured readily
and reliably from the display. Per
formance
of
a diode in a particular circuit can
be pre
dicted
by
analyzing the recovery and "turn-on"
character
istics.
Since it is
essentially a means for plotting voltage
across an
element while passing constant
current through
it,
the unit
can be used for other applications as well. For
example:
observing
the junction characteristics
of
transistors,
1-3
Summary of Contents for 535A
Page 2: ......
Page 4: ...Type 535A ...
Page 28: ...Circuit Description Type 535A 4 2 Fig 4 1 Simplified Type 535A Vertical Amplifier ...
Page 30: ...Circuit Description Type 535A 4 4 Fig 4 2 Simplified Time Base Trigger Circuit ...
Page 32: ...Circuit Description Type 535A Fig 4 3 Simplified Time Base Generator 4 6 ...
Page 34: ...Circuit Description Type 535A 4 8 Fig 4 4 Simplified Delay Pickoff Circuit ...
Page 38: ...Circuit Description Type 535A Fig 4 6 Simplified Alternate Trace Operation Circuitry 4 12 ...
Page 39: ...Circuit Description Type 535A 4 13 ...
Page 41: ...Circuit Description Type 535A Fig 4 8 Simplified Low Voltage Power Supply 4 15 ...
Page 42: ...Circuit Description Type 535A 4 16 Fig 4 9 Simplified Calibrator Circuit ...
Page 44: ...Circuit Description Type 535A Fig 4 10 Simplified Cathode Ray Tube Circuit 4 18 ...
Page 126: ...MRU ll IG 61 O Z ...
Page 138: ...C897 R896 R891 R890 R889 R888 R887 R886 R885 AMPLITUDE CALIBRATOR SWITCH Bottom View 535A A ...
Page 143: ...FIG 1 FRONT SWITCHES TVDC COCA ocril I iCrODC ...
Page 144: ...70 ...
Page 145: ...1 FIG 3 SWEEP CHASSIS HIGH VOLTAGE BOARD DELAY SWEEP CHASSIS ...
Page 146: ...1 FIG 4 POWER CHASSIS RECTIFIER MOUNTING PLATE A ...
Page 147: ...3 34 79 ...
Page 148: ...TYPE 535A OSCILLOSCOPE ...
Page 149: ......
Page 150: ...FIG 7 CABINET FRAME RAILS ...
Page 152: ...FIG 8 STANDARD ACCESSORIES 6 TYPE 535A OSCILLOSCOPE ...