Calibration
Procedure—
Type
535A
shift
of the trace while turning
the horizontal
VARIABLE 10-
1 front-panel
control.
17.
Check
EXT. HORIZ. INPUT Deflection factor
With
conditions
as in Step 16 above, connect a jumper
from
CAL. OUT
to HORIZ. INPUT, set CALIBRATOR for .2
volt and turn VARIABLE
10-1 control full right.
At least one
centimeter
of horizontal
deflection
must
be observed be
tween
the two vertical
lines. Increase the CALIBRATOR to
2 VOLTS
and adjust VARIABLE 10-1 for exactly 10 cm of
horizontal deflection between
the vertical
lines. Now switch
HORIZONTAL
DISPLAY to
EXT. X10. Horizontal deflection
should
now be 1 centimeter. (Attenuator accuracy ±2%).
18.
Adjust External Horizontal Input Compen
sation
Connect
a jumper from
the 'A' SAWTOOTH to the vertical
INPUT.
Feed
.5
VOLT from CAL. OUT. to both HORIZ.
INPUT
and
'A'
TRIGGER INPUT. Set controls as follows:
HORIZONTAL
DISPLAY
EXT.
XI
TRIGGER SLOPE
(A)
—EXT.
TIME/CM
1
MILLISEC
VOLTS/CM (Plug-In)
10
Adjust 'A'
STABILITY
and TRIGGERING LEVEL
controls for
a stable
square-wave,
displayed vertically. Adjust C330
(see
Top
View,
Fig.
6-3) for optimum square wave response.
Now
switch the HORIZONTAL DISPLAY to
EXT. XI0, in
crease CALIBRATOR signal
to 5 VOLTS,
and adjust C301C
(see Right
Side View, Fig.
6-2) for optimum flattop.
19.
Adjust
Sweep
Calibration
Set controls
as follows:
TIME/CM
(B)
1
MILLISEC
TRIGGER
SLOPE
+INT
5X
MAGNIFIER
OFF
Connect 1 millisecond
markers
from the Type 180A to the
Vertical
INPUT
and adjust ‘B1 triggering
for a stable display.
Adjust
Sweep
Cal.
(see Right Side View, Fig. 6-2) for 1 time
marker
per centimeter. After this adjustment is
made, the
5X
Mag. Gain and the Sweep Mag. Register should be
rechecked.
(Steps
14 and
15.)
20.
Adjust
Time Base A Sweep Rate
Switch
HORIZONTAL DISPLAY
to A, set
TIME/CM to 1
MILLISEC,
VARIABLE
to CALIBRATED,
and adjust A' trigger
ing for a stable display.
Adjust R160Z (see Right Side View,
Fig. 6-2)
for the same timing as that obtained
for the ‘B
sweep
in Step 19 above,
±5%.
21.
Adjust
Time
Base A Sweep Length
With
control as in Step
20 above, adjust the Sweep Length
control
(see Top View, Fig. 6-3) for a sweep length of 10.5
centimeters.
22.
Check
Time
Base B Sweep Rates
Starting
with conditions as in Step 19 above, check TIME
BASE
B sweep
rates according to the following table:
TIME
BASE
B
TYPE
180A
Markers
displayed
1
MILLISEC
1
MILLISECOND
1 /cm
2 MILLISEC
1
MILLISECOND
2/cm
5 MILLISEC
5 MILLISECOND
1 /cm
10
MILLISEC
10
MILLISECOND
1
/cm
20 MILLISEC
10 MILLISECOND
2/cm
50 MILLISEC
50
MILLISECOND
1 /cm
.1 SEC
100 MILLISECOND
1
/cm
.2 SEC
100 MILLISECOND
2/cm
.5
SEC
500
MILLISECOND
1
/cm
1
SEC
1
SECOND
1
/cm
23.
Check
Time
Base A Sweep Rates
Starting with conditions
as
in Step 20 above, check
TIME
BASE A
sweep
rates according to the following table:
TIME BASE
A
TYPE
180A
Markers
displayed
1 MILLISEC
1
MILLISECOND
1 /cm
2
MILLISEC
1
MILLISECOND
2/cm
5 MILLISEC
5
MILLISECOND
1
/cm
10 MILLISEC
10 MILLISECOND
1
/cm
20 MILLISEC
10
MILLISECOND
2/cm
50 MILLISEC
50 MILLISECOND
1
/cm
.1
SECOND
100
MILLISECOND
1 /cm
.2 SECOND
100
MILLISECOND
2/cm
.5 SECOND
500 MILLISECOND
1
/cm
1
SECOND
1
SECOND
1
/cm
2 SECOND
1
SECOND
2/cm
5 SECOND
5 SECOND
1 /cm
NOTE
Any
non-linearity
present
in
the
sweep
will
always
be
in
the
first
and
last
centimeter.
Consequently,
all timing
adjustments
should
be
made
from
the 1
cm
line
to
the
9
cm
line
in
the graticule.
24.
Check Time Base A
—Variable
Time/CM
control
and Uncalibrated Neon.
The VARIABLE control
provides for a complete range
of
control between
the calibrated TIME/CM steps. To check
operation
of
this control, set TIME/CM to 1 MILLISEC—CALI
6-7
Summary of Contents for 535A
Page 2: ......
Page 4: ...Type 535A ...
Page 28: ...Circuit Description Type 535A 4 2 Fig 4 1 Simplified Type 535A Vertical Amplifier ...
Page 30: ...Circuit Description Type 535A 4 4 Fig 4 2 Simplified Time Base Trigger Circuit ...
Page 32: ...Circuit Description Type 535A Fig 4 3 Simplified Time Base Generator 4 6 ...
Page 34: ...Circuit Description Type 535A 4 8 Fig 4 4 Simplified Delay Pickoff Circuit ...
Page 38: ...Circuit Description Type 535A Fig 4 6 Simplified Alternate Trace Operation Circuitry 4 12 ...
Page 39: ...Circuit Description Type 535A 4 13 ...
Page 41: ...Circuit Description Type 535A Fig 4 8 Simplified Low Voltage Power Supply 4 15 ...
Page 42: ...Circuit Description Type 535A 4 16 Fig 4 9 Simplified Calibrator Circuit ...
Page 44: ...Circuit Description Type 535A Fig 4 10 Simplified Cathode Ray Tube Circuit 4 18 ...
Page 126: ...MRU ll IG 61 O Z ...
Page 138: ...C897 R896 R891 R890 R889 R888 R887 R886 R885 AMPLITUDE CALIBRATOR SWITCH Bottom View 535A A ...
Page 143: ...FIG 1 FRONT SWITCHES TVDC COCA ocril I iCrODC ...
Page 144: ...70 ...
Page 145: ...1 FIG 3 SWEEP CHASSIS HIGH VOLTAGE BOARD DELAY SWEEP CHASSIS ...
Page 146: ...1 FIG 4 POWER CHASSIS RECTIFIER MOUNTING PLATE A ...
Page 147: ...3 34 79 ...
Page 148: ...TYPE 535A OSCILLOSCOPE ...
Page 149: ......
Page 150: ...FIG 7 CABINET FRAME RAILS ...
Page 152: ...FIG 8 STANDARD ACCESSORIES 6 TYPE 535A OSCILLOSCOPE ...