Measuring Waveforms
TDS 500D, TDS 600B, & TDS 700D User Manual
3–127
Table 3–11: Measurement definitions (cont.)
Name
Definition
Cycle RMS
Voltage measurement. The true Root Mean Square voltage over the first cycle in the waveform
or the first cycle in the gated region.
Delay
Timing measurement. The time between the MidRef crossings of two different traces or the
gated region of the traces.
Fall Time
Timing measurement. Time taken for the falling edge of the first pulse in the waveform or gated
region to fall from a High Ref value (default = 90%) to a Low Ref value (default =10%) of its
final value.
Frequency
Timing measurement for the first cycle in the waveform or gated region. The reciprocal of the
period. Measured in Hertz (Hz) where 1 Hz = 1 cycle per second.
High
The value used as 100% whenever High Ref, Mid Ref, and Low Ref values are needed (as in fall
time and rise time measurements). Calculated using either the min/max or the histogram method.
The min/max method uses the maximum value found. The histogram method uses the most
common value found above the mid point. Measured over the entire waveform or gated region.
Low
The value used as 0% whenever High Ref, Mid Ref, and Low Ref values are needed (as in fall
time and rise time measurements). May be calculated using either the min/max or the histogram
method. With the min/max method it is the minimum value found. With the histogram method, it
refers to the most common value found below the midpoint. Measured over the entire waveform
or gated region.
Maximum
Voltage measurement. The maximum amplitude. Typically the most positive peak voltage.
Measured over the entire waveform or gated region.
Mean
Voltage measurement. The arithmetic mean over the entire waveform or gated region.
Minimum
Voltage measurement. The minimum amplitude. Typically the most negative peak voltage.
Measured over the entire waveform or gated region.
Negative Duty Cycle
Timing measurement of the first cycle in the waveform or gated region. The ratio of the negative
pulse width to the signal period expressed as a percentage.
NegativeDutyCycle
+
NegativeWidth
Period
100%
Negative Overshoot
Voltage measurement. Measured over the entire waveform or gated region.
NegativeOvershoot
+
Low
*
Min
Amplitude
100%
Negative Width
Timing measurement of the first pulse in the waveform or gated region. The distance (time)
between MidRef (default 50%) amplitude points of a negative pulse.
Peak to Peak
Voltage measurement. The absolute difference between the maximum and minimum amplitude
in the entire waveform or gated region.
Summary of Contents for 071-0130-00
Page 4: ......
Page 12: ...Table of Contents viii TDS 500D TDS 600B TDS 700D User Manual ...
Page 18: ...Preface xiv TDS 500D TDS 600B TDS 700D User Manual ...
Page 19: ...Getting Started ...
Page 28: ...Operating Basics ...
Page 30: ...Overview 2 2 TDS 500D TDS 600B TDS 700D User Manual ...
Page 60: ...Tutorial 2 32 TDS 500D TDS 600B TDS 700D User Manual ...
Page 61: ...Reference ...
Page 65: ...Overview 3 4 TDS 500D TDS 600B TDS 700D User Manual ...
Page 185: ...Triggering on Waveforms 3 124 TDS 500D TDS 600B TDS 700D User Manual ...
Page 257: ...Saving Waveforms and Setups 3 196 TDS 500D TDS 600B TDS 700D User Manual ...
Page 300: ...Appendices ...
Page 310: ...Appendix A Options and Accessories A 10 TDS 500D TDS 600B TDS 700D User Manual ...
Page 328: ...Appendix B Algorithms B 18 TDS 500D TDS 600B TDS 700D User Manual ...
Page 330: ...Appendix C Packaging for Shipment C 2 TDS 500D TDS 600B TDS 700D User Manual ...
Page 340: ...Appendix F Programmer Disk F 2 TDS 500D TDS 600B TDS 700D User Manual ...
Page 341: ...Glossary ...
Page 355: ...Glossary Glossary 14 TDS 500D TDS 600B TDS 700D User Manual ...
Page 356: ...Index ...
Page 374: ...Index Index 18 TDS 500D TDS 600B TDS 700D User Manual ...
Page 375: ......
Page 376: ......