background image

Instruction Manual 

Tek-DP 1650A

 

www.tek-trol.com 

Technology Solutions

1.4.3

 

Storage 

If this product is to be stored for a long period of time before installation, take the following 

precautions: 

Store your product in the manufacturer’s original packing used for shipping.

Storage location should conform to the following requirements:

1. Free from rain and water

2. Free from vibration and impact shock

3. At room temperature with minimal temperature and humidity variation

Before storing a used flowmeter remove any fluid from the flowmeter line completely.

Properties of the instrument can change when stored outdoors.

1.4.4

 

Nameplate 

The nameplate lists the order number and other important information, such as design details 

and technical data. 

NOTE 

Check the device nameplate to ensure that the device is delivered according to your 

order. Check for the correct supply voltage printed on the nameplate. 

2

 

Product Description 

This section covers the reference and specification data, as well as ordering information. 

2.1

 

Introduction 

The Tek-DP 1650A DProbar Multiport Self-Averaging Flow Meter functions as an obstruction that 

changes the cross-section of the flow of the liquid in the pipe or conduit. In a differential pressure 

flow meter, as the liquid passes through the obstruction, its potential energy is converted into 

kinetic energy. The velocity of the liquid increases and is accompanied by a simultaneous decrease 

in the pressure. When the liquid exits the obstruction, the velocity decreases, and the pressure 

increases again. These pressure drops generated across the obstacle are proportional to the flow 

rate square and calculated using Bernoulli's equation. 

2.2

 

Measuring Principle 

While the Tek-DP 1650A DProbar measures the pressure of a liquid at a single point, the more 

modern averaging Tek-DP 1650A DProbar measures the average pressure by taking sample values 

at different points in the pipe. It is inserted directly into the pipe and is perpendicular to the 

direction of flow. The side of the tube facing the flow of the liquid consists of  several impact 

pressure ports while the opposite side of the tube may have a single or multiple static pressure 

ports. These ports are connected together to a secondary device such as a differential pressure 

transmitter. 

When the liquid comes in contact with the tube, the kinetic energy of the liquid is converted into 

potential energy and velocity is reduced to zero. The pressure now measured at the upstream 

ports is called the total impact pressure, which is the sum of the static pressure and the dynamic 

Summary of Contents for TEK-DP1650A

Page 1: ...Technology Solutions T 1650A EK DP Instruction Manual DProbar Multiport Self Averaging Flow Meter Document Number IM 1650A www tek trol com...

Page 2: ...contact Customer Support 796 Tek Drive Crystal Lake IL 60014 USA Tel 1 847 857 6076 www tek trol com No part of this publication may be copied or distributed transmitted transcribed stored in a retri...

Page 3: ...n 3 1 4 3 Storage 4 1 4 4 Nameplate 4 2 Product Description 4 2 1 Introduction 4 2 2 Measuring Principle 4 2 3 Dimensional Drawings 5 2 4 Specifications 6 2 5 Model chart 6 3 Installation 8 3 1 Select...

Page 4: ...cation The manufacturer accepts no liability for the consequences of misuse by the operator Wrong installation or operation of the devices systems will cause the warranty to be void The respective Ter...

Page 5: ...er may damage it or lead to system failure 1 4 Packaging Transportation and Storage 1 4 1 Packaging The original package consists of 1 Tek DP 1650A DProbar Multiport Self Averaging Flow Meter 2 Docume...

Page 6: ...he pipe or conduit In a differential pressure flow meter as the liquid passes through the obstruction its potential energy is converted into kinetic energy The velocity of the liquid increases and is...

Page 7: ...flow rate of the liquid using the following formulas To calculate the volumetric flow rate QA N K D2 Faa DP GF For liquids QA N K D2 Faa DP F For gases To calculate the mass flow rate QMASS N K D2 Ya...

Page 8: ...available including Brass steel stainless steel and Hastelloy Bolt Material ASTM A193 B7 ASTM A194 2H ASTM A193 B8M ASTM A194 8MA Process Connection Flanged Weld prepared ends Threaded BSPT Threaded...

Page 9: ...ss Connections A 1 mNPT B 1 150 Flange C 1 weldolet Temperature Measurement O No Temperature Sensor T Integral RTD X Remote thermowell and RTD Flow Transmitters Computers 01 None Customer Supplied 02...

Page 10: ...rdous processes avoid direct contact with the fluid and the meter All installation must comply with local installation requirements and local electrical code WARNING This section offers instructions f...

Page 11: ...stream of Fluid Bar are given in Table 1 Use of recommended straight pipe lengths of uniform diameter ensures that the flow measurement will be made with fully developed characteristics Included gate...

Page 12: ...n Manual Tek DP 1650A www tek trol com Technology Solutions 10 3 1 2 TYPE FBR 73 FBR 75 FLUID BAR 3 1 3 TYPE FBR 76 FLUID BAR Fig 5 Type FBR 73 Fluid Bar Fig 7 Type FBR 76 Fluid Bar Fig 6 Type FBR 75...

Page 13: ...trol com Technology Solutions 11 3 1 4 TYPE FBF 61 FLUID BAR 3 1 5 TYPE FBF 75 FBF 76 FLUID BAR 3 1 6 TYPE FBF 85 FLUID BAR Fig 8 Type FBF 61 Fluid Bar Fig 9 Type FBF 75 Fluid Bar Fig 10 Type FBF 76...

Page 14: ...d support is aligned perpendicular to the pipe axis in line with the weld coupling 5 Install the Flow Tap unit isolating valve on the process connection Verify that the valve is in the fully open posi...

Page 15: ...22mm hole 4 Electrical Connection This section covers the all electrical connection requirement Electrical connection of the device must be carried out by trained qualified specialists authorized to p...

Page 16: ...To ensure meeting stated accuracy alignment must be within limits shown below Pipe size The Fluid Bar may have been designed for a different pipe size than that in which it is being used Measure pipe...

Page 17: ...ts and solutions for process power and oil gas industries Tek Trol provides process measurement and control products for Flow Level Temperature Pressure Measurement Control Valves Analyzer systems We...

Reviews: