background image

Instruction Manual 

  

 

 

 

 

 

 

 

Tek-DP 1650A

 

 

www.tek-trol.com 

Technology Solutions

1

 

Safety Instructions 

1.1

 

Intended Use 

Tek-DP 1650A DProbar Multiport Self-Averaging Flow Meter measures the average pressure by 

taking sample values at different points in the pipe. 

 

1.2

 

Safety Instructions from the Manufacturer 

1.2.1

 

Disclaimer 

The manufacturer will not be held accountable for any damage that happens by using its product, 

including  but not limited to direct, indirect, or incidental and consequential damages.  Any 

product purchased from the manufacturer is warranted in accordance with the relevant product 

documentation and our Terms and Conditions of Sale. 

The manufacturer has the right to modify the content of this document, including the disclaimer, 

at any time for any reason without prior notice, and will not be answerable in any way for the 

possible consequence of such changes. 

 

1.2.2

 

Product Liability and Warranty 

The operator shall bear authority for the suitability of the device for the specific application. The 

manufacturer accepts no liability for the consequences of misuse by the operator. Wrong 

installation or operation of the devices (systems) will cause the warranty to be void. The 

respective Terms and Conditions of Sale, which form the basis for the sales contract shall also 

apply. 

 

1.2.3

 

Information Concerning the Documentation 

To prevent any injury to the operator or damage to the device it is essential to read the 

information in this document and the applicable national standard safety instructions. This 

operating manual contains all the information needed in various stages, such as product 

identification, incoming acceptance and storage, mounting, connection, operation, and 

commissioning, troubleshooting, maintenance, and disposal. 

 

1.3

 

Safety Precautions 

You must read these instructions carefully before installing and commissioning the device. These 
instructions are an important part of the product and must be kept for future reference. Only by 
observing these instructions, optimum protection of both personnel and the environment, as well 
as safe and fault-free operation of the device can be ensured. 
For additional information that is not discussed in this manual, contact the manufacturer. 
 

 

 

Summary of Contents for TEK-DP1650A

Page 1: ...Technology Solutions T 1650A EK DP Instruction Manual DProbar Multiport Self Averaging Flow Meter Document Number IM 1650A www tek trol com...

Page 2: ...contact Customer Support 796 Tek Drive Crystal Lake IL 60014 USA Tel 1 847 857 6076 www tek trol com No part of this publication may be copied or distributed transmitted transcribed stored in a retri...

Page 3: ...n 3 1 4 3 Storage 4 1 4 4 Nameplate 4 2 Product Description 4 2 1 Introduction 4 2 2 Measuring Principle 4 2 3 Dimensional Drawings 5 2 4 Specifications 6 2 5 Model chart 6 3 Installation 8 3 1 Select...

Page 4: ...cation The manufacturer accepts no liability for the consequences of misuse by the operator Wrong installation or operation of the devices systems will cause the warranty to be void The respective Ter...

Page 5: ...er may damage it or lead to system failure 1 4 Packaging Transportation and Storage 1 4 1 Packaging The original package consists of 1 Tek DP 1650A DProbar Multiport Self Averaging Flow Meter 2 Docume...

Page 6: ...he pipe or conduit In a differential pressure flow meter as the liquid passes through the obstruction its potential energy is converted into kinetic energy The velocity of the liquid increases and is...

Page 7: ...flow rate of the liquid using the following formulas To calculate the volumetric flow rate QA N K D2 Faa DP GF For liquids QA N K D2 Faa DP F For gases To calculate the mass flow rate QMASS N K D2 Ya...

Page 8: ...available including Brass steel stainless steel and Hastelloy Bolt Material ASTM A193 B7 ASTM A194 2H ASTM A193 B8M ASTM A194 8MA Process Connection Flanged Weld prepared ends Threaded BSPT Threaded...

Page 9: ...ss Connections A 1 mNPT B 1 150 Flange C 1 weldolet Temperature Measurement O No Temperature Sensor T Integral RTD X Remote thermowell and RTD Flow Transmitters Computers 01 None Customer Supplied 02...

Page 10: ...rdous processes avoid direct contact with the fluid and the meter All installation must comply with local installation requirements and local electrical code WARNING This section offers instructions f...

Page 11: ...stream of Fluid Bar are given in Table 1 Use of recommended straight pipe lengths of uniform diameter ensures that the flow measurement will be made with fully developed characteristics Included gate...

Page 12: ...n Manual Tek DP 1650A www tek trol com Technology Solutions 10 3 1 2 TYPE FBR 73 FBR 75 FLUID BAR 3 1 3 TYPE FBR 76 FLUID BAR Fig 5 Type FBR 73 Fluid Bar Fig 7 Type FBR 76 Fluid Bar Fig 6 Type FBR 75...

Page 13: ...trol com Technology Solutions 11 3 1 4 TYPE FBF 61 FLUID BAR 3 1 5 TYPE FBF 75 FBF 76 FLUID BAR 3 1 6 TYPE FBF 85 FLUID BAR Fig 8 Type FBF 61 Fluid Bar Fig 9 Type FBF 75 Fluid Bar Fig 10 Type FBF 76...

Page 14: ...d support is aligned perpendicular to the pipe axis in line with the weld coupling 5 Install the Flow Tap unit isolating valve on the process connection Verify that the valve is in the fully open posi...

Page 15: ...22mm hole 4 Electrical Connection This section covers the all electrical connection requirement Electrical connection of the device must be carried out by trained qualified specialists authorized to p...

Page 16: ...To ensure meeting stated accuracy alignment must be within limits shown below Pipe size The Fluid Bar may have been designed for a different pipe size than that in which it is being used Measure pipe...

Page 17: ...ts and solutions for process power and oil gas industries Tek Trol provides process measurement and control products for Flow Level Temperature Pressure Measurement Control Valves Analyzer systems We...

Reviews: